CVE-2024-4872

Published Aug 27, 2024 CVSS 3.1 · 8.8 High EPSS < 1% KEV · Not listed
Description
A vulnerability exists in the query validation of the MicroSCADA Pro/X SYS600 product. If exploited this could allow an authenticated attacker to inject code towards persistent data. Note that to successfully exploit this vulnerability
an attacker must have a valid credential.

Remediation

No solution or workaround provided in the CVE record

Tracking

Sign in to view the affected projects.

Advisories

Source ID Title
EUVD EUVD EUVD-2024-44446 A vulnerability exists in the query validation of the MicroSCADA Pro/X SYS600 product. If exploited this could allow an authenticated attacker to inject code towards persistent data. Note that to successfully exploit this vulnerability an attacker must have a valid credential.
History
Type Values Removed Values Added
First Time appeared Hitachienergy microscada Pro Sys600
Weaknesses CWE-89 NVD-CWE-Other
CPEs cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:fixpack_2_hf1:*:*:*:*:*:*
cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:fixpack_2_hf2:*:*:*:*:*:*
cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:fixpack_2_hf3:*:*:*:*:*:*
cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:fixpack_2_hf4:*:*:*:*:*:*
cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:fixpack_2_hf5:*:*:*:*:*:*
Vendors & Products Hitachienergy microscada Pro Sys600
Type Values Removed Values Added
Description The product does not validate any query towards persistent data, resulting in a risk of injection attacks. A vulnerability exists in the query validation of the MicroSCADA Pro/X SYS600 product. If exploited this could allow an authenticated attacker to inject code towards persistent data. Note that to successfully exploit this vulnerability an attacker must have a valid credential.
Metrics cvssV3_1

{'score': 9.9, 'vector': 'CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H'}

cvssV3_1

{'score': 8.8, 'vector': 'CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H'}

Type Values Removed Values Added
Weaknesses CWE-943
Type Values Removed Values Added
First Time appeared Hitachienergy microscada X Sys600
CPEs cpe:2.3:a:hitachienergy:microscada_x_sys600:*:*:*:*:*:*:*:*
Vendors & Products Hitachienergy microscada X Sys600
Type Values Removed Values Added
First Time appeared Hitachienergy
Hitachienergy microscada Sys600
CPEs cpe:2.3:a:hitachienergy:microscada_sys600:*:*:*:*:*:*:*:*
Vendors & Products Hitachienergy
Hitachienergy microscada Sys600
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'none', 'Technical Impact': 'total'}, 'version': '2.0.3'}

Type Values Removed Values Added
Description The product does not validate any query towards persistent data, resulting in a risk of injection attacks.
Weaknesses CWE-89
References
Metrics cvssV3_1

{'score': 9.9, 'vector': 'CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H'}

Weaknesses

Sources

Status
PUBLISHED
Assigner
Hitachi Energy
Published
Updated
Aug 27, 2025, 9:30 PM
Reserved
May 14, 2024, 2:41 PM
Status
Analyzed
Published
Aug 27, 2024, 1:15 PM
Modified
Jun 17, 2026, 8:03 AM