Default status is the baseline for the product, each version can override it (e.g. patched versions marked unaffected).
| Vendor | Product | Default status | Versions | ||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | InterMesh 7177 Hybrid 2.0 Subscriber | unknown |
|
||||||
| Siemens | InterMesh 7707 Fire Subscriber | unknown |
|
Configuration 1 [-]
| AND |
|
Configuration 2 [-]
| AND |
|
No data.
No data available yet.
| Source | ID | Title |
|---|---|---|
EUVD |
EUVD-2024-42717 | A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The web server of affected devices does not authenticate GET requests that execute specific commands (such as `ping`) on operating system level. |
No CVSS v3.0
No CVSS v2
This CVE is not in the KEV list.
Exploit prediction score: < 1% (0.512% probability within 30 days)
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Siemens intermesh 7177 Hybrid 2.0 Subscriber
Siemens intermesh 7707 Fire Subscriber Firmware |
|
| CPEs | cpe:2.3:h:siemens:intermesh_7177_hybrid_2.0_subscriber:-:*:*:*:*:*:*:* cpe:2.3:h:siemens:intermesh_7707_fire_subscriber:-:*:*:*:*:*:*:* cpe:2.3:o:siemens:intermesh_7177_hybrid_2.0_subscriber:*:*:*:*:*:*:*:* cpe:2.3:o:siemens:intermesh_7707_fire_subscriber_firmware:*:*:*:*:*:*:*:* |
|
| Vendors & Products |
Siemens intermesh 7177 Hybrid 2.0 Subscriber
Siemens intermesh 7707 Fire Subscriber Firmware |
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Siemens
Siemens intermesh 7177 Hybrid2.0 Subscriber Siemens intermesh 7707 Fire Subscriber |
|
| CPEs | cpe:2.3:a:siemens:intermesh_7177_hybrid2.0_subscriber:*:*:*:*:*:*:*:* cpe:2.3:a:siemens:intermesh_7707_fire_subscriber:*:*:*:*:*:*:*:* |
|
| Vendors & Products |
Siemens
Siemens intermesh 7177 Hybrid2.0 Subscriber Siemens intermesh 7707 Fire Subscriber |
|
| Metrics |
ssvc
|
| Type | Values Removed | Values Added |
|---|---|---|
| Description | A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The web server of affected devices does not authenticate GET requests that execute specific commands (such as `ping`) on operating system level. | |
| Weaknesses | CWE-306 | |
| References |
| |
| Metrics |
cvssV3_1
|