Default status is the baseline for the product, each version can override it (e.g. patched versions marked unaffected).
| Vendor | Product | Default status | Versions | ||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | InterMesh 7177 Hybrid 2.0 Subscriber | unknown |
|
||||||
| Siemens | InterMesh 7707 Fire Subscriber | unknown |
|
Configuration 1 [-]
| AND |
|
Configuration 2 [-]
| AND |
|
No data.
No data available yet.
| Source | ID | Title |
|---|---|---|
EUVD |
EUVD-2024-42716 | A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The web server of affected devices does not sanitize the input parameters in specific GET requests that allow for code execution on operating system level. In combination with other vulnerabilities (CVE-2024-47902, CVE-2024-47903, CVE-2024-47904) this could allow an unauthenticated remote attacker to execute arbitrary code with root privileges. |
No CVSS v3.0
No CVSS v2
This CVE is not in the KEV list.
Exploit prediction score: 1.2% (1.249% probability within 30 days)
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Siemens intermesh 7177 Hybrid 2.0 Subscriber
Siemens intermesh 7707 Fire Subscriber Firmware |
|
| CPEs | cpe:2.3:h:siemens:intermesh_7177_hybrid_2.0_subscriber:-:*:*:*:*:*:*:* cpe:2.3:h:siemens:intermesh_7707_fire_subscriber:-:*:*:*:*:*:*:* cpe:2.3:o:siemens:intermesh_7177_hybrid_2.0_subscriber:*:*:*:*:*:*:*:* cpe:2.3:o:siemens:intermesh_7707_fire_subscriber_firmware:*:*:*:*:*:*:*:* |
|
| Vendors & Products |
Siemens intermesh 7177 Hybrid 2.0 Subscriber
Siemens intermesh 7707 Fire Subscriber Firmware |
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Siemens
Siemens intermesh 7177 Hybrid2.0 Subscriber Siemens intermesh 7707 Fire Subscriber |
|
| CPEs | cpe:2.3:a:siemens:intermesh_7177_hybrid2.0_subscriber:*:*:*:*:*:*:*:* cpe:2.3:a:siemens:intermesh_7707_fire_subscriber:*:*:*:*:*:*:*:* |
|
| Vendors & Products |
Siemens
Siemens intermesh 7177 Hybrid2.0 Subscriber Siemens intermesh 7707 Fire Subscriber |
|
| Metrics |
ssvc
|
| Type | Values Removed | Values Added |
|---|---|---|
| Description | A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The web server of affected devices does not sanitize the input parameters in specific GET requests that allow for code execution on operating system level. In combination with other vulnerabilities (CVE-2024-47902, CVE-2024-47903, CVE-2024-47904) this could allow an unauthenticated remote attacker to execute arbitrary code with root privileges. | |
| Weaknesses | CWE-78 | |
| References |
| |
| Metrics |
cvssV3_1
|