Default status is the baseline for the product, each version can override it (e.g. patched versions marked unaffected).
| Vendor | Product | Default status | Versions | ||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | Teamcenter Visualization V14.2 | unknown |
|
||||||
| Siemens | Teamcenter Visualization V14.3 | unknown |
|
||||||
| Siemens | Teamcenter Visualization V2312 | unknown |
|
||||||
| Siemens | Tecnomatix Plant Simulation V2302 | unknown |
|
||||||
| Siemens | Tecnomatix Plant Simulation V2404 | unknown |
|
Configuration 1 [-]
|
No data.
No data available yet.
| Source | ID | Title |
|---|---|---|
EUVD |
EUVD-2024-41716 | A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. |
No CVSS v3.0
No CVSS v2
This CVE is not in the KEV list.
Exploit prediction score: < 1% (0.245% probability within 30 days)
| Type | Values Removed | Values Added |
|---|---|---|
| Description | A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. | A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. |
| References |
|
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Siemens
Siemens tecnomatix Plant Simulation |
|
| CPEs | cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:* | |
| Vendors & Products |
Siemens
Siemens tecnomatix Plant Simulation |
|
| Metrics |
ssvc
|
| Type | Values Removed | Values Added |
|---|---|---|
| Description | A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. | |
| Weaknesses | CWE-125 | |
| References |
| |
| Metrics |
cvssV3_1
|