Default status is the baseline for the product, each version can override it (e.g. patched versions marked unaffected).
| Vendor | Product | Default status | Versions | ||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | Automation License Manager V5 | unknown |
|
||||||
| Siemens | Automation License Manager V6.0 | unknown |
|
||||||
| Siemens | Automation License Manager V6.2 | unknown |
|
No data.
No data.
No data available yet.
| Source | ID | Title |
|---|---|---|
EUVD |
EUVD-2024-40855 | A vulnerability has been identified in Automation License Manager V5 (All versions), Automation License Manager V6.0 (All versions), Automation License Manager V6.2 (All versions < V6.2 Upd3). Affected applications do not properly validate certain fields in incoming network packets on port 4410/tcp. This could allow an unauthenticated remote attacker to cause an integer overflow and crash of the application. This denial of service condition could prevent legitimate users from using subsequent products that rely on the affected application for license verification. |
No CVSS v3.0
No CVSS v2
This CVE is not in the KEV list.
Exploit prediction score: 10.9% (10.873% probability within 30 days)
| Type | Values Removed | Values Added |
|---|---|---|
| Description | A vulnerability has been identified in Automation License Manager V5 (All versions), Automation License Manager V6.0 (All versions), Automation License Manager V6.2 (All versions < V6.2 Upd3). Affected applications do not properly validate certain fields in incoming network packets on port 4410/tcp. This could allow an unauthenticated remote attacker to cause an integer overflow and crash of the application. This denial of service condition could prevent legitimate users from using subsequent products that rely on the affected application for license verification. | A vulnerability has been identified in Automation License Manager V5 (All versions), Automation License Manager V6.0 (All versions < V6.0 SP12 Upd3), Automation License Manager V6.2 (All versions < V6.2 Upd3). Affected applications do not properly validate certain fields in incoming network packets on port 4410/tcp. This could allow an unauthenticated remote attacker to cause an integer overflow and crash of the application. This denial of service condition could prevent legitimate users from using subsequent products that rely on the affected application for license verification. |
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Siemens
Siemens automation License Manager |
|
| CPEs | cpe:2.3:a:siemens:automation_license_manager:*:*:*:*:*:*:*:* | |
| Vendors & Products |
Siemens
Siemens automation License Manager |
|
| Metrics |
ssvc
|
| Type | Values Removed | Values Added |
|---|---|---|
| Description | A vulnerability has been identified in Automation License Manager V5 (All versions), Automation License Manager V6.0 (All versions), Automation License Manager V6.2 (All versions < V6.2 Upd3). Affected applications do not properly validate certain fields in incoming network packets on port 4410/tcp. This could allow an unauthenticated remote attacker to cause an integer overflow and crash of the application. This denial of service condition could prevent legitimate users from using subsequent products that rely on the affected application for license verification. | |
| Weaknesses | CWE-190 | |
| References |
| |
| Metrics |
cvssV3_1
|