Optigo Networks ONS-S8 Spectra Aggregation Switch PHP Remote File Inclusion
Default status is the baseline for the product, each version can override it (e.g. patched versions marked unaffected).
| Vendor | Product | Default status | Versions | ||||||
|---|---|---|---|---|---|---|---|---|---|
| Optigo Networks | ONS-S8 Spectra Aggregation Switch | unaffected |
|
No data.
No data.
No data available yet.
Vendor Workaround
Optigo Networks recommends users always use a unique management VLAN for the port on the ONS-S8 that is used to connect to OneView. Optigo Networks also recommends users implement at least one of the following additional mitigations: * Use a dedicated NIC on the BMS computer and exclusively this computer for connecting to OneView to manage your OT network configuration. * Set up a router firewall with a white list for the devices permitted to access OneView. * Connect to OneView via secure VPN.
| Source | ID | Title |
|---|---|---|
EUVD |
EUVD-2024-39277 | The web service for ONS-S8 - Spectra Aggregation Switch includes functions which do not properly validate user input, allowing an attacker to traverse directories, bypass authentication, and execute remote code. |
No CVSS v3.0
No CVSS v2
This CVE is not in the KEV list.
Exploit prediction score: < 1% (0.696% probability within 30 days)
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Optigo
Optigo ons-s8 Firmware |
|
| CPEs | cpe:2.3:o:optigo:ons-s8_firmware:*:*:*:*:*:*:*:* | |
| Vendors & Products |
Optigo
Optigo ons-s8 Firmware |
|
| Metrics |
ssvc
|
| Type | Values Removed | Values Added |
|---|---|---|
| Description | The web service for ONS-S8 - Spectra Aggregation Switch includes functions which do not properly validate user input, allowing an attacker to traverse directories, bypass authentication, and execute remote code. | |
| Title | Optigo Networks ONS-S8 Spectra Aggregation Switch PHP Remote File Inclusion | |
| Weaknesses | CWE-98 | |
| References |
| |
| Metrics |
cvssV3_1
|