{"affected": [{"affectedData": [{"collectionURL": "https://new.abb.com/products/de/2TMA310010B0001/sd-u12-55-11-825", "defaultStatus": "unaffected", "platforms": ["proprietary"], "product": "2.4! Display 55, SD/U12.55.11-825", "vendor": "ABB, Busch-Jaeger", "versions": [{"status": "affected", "version": "1.00", "versionType": "custom"}]}, {"collectionURL": "https://new.abb.com/products/de/2TMA310011B0001/sd-u12-55-1-825", "defaultStatus": "unaffected", "platforms": ["proprietary"], "product": "2.4! Display 55, SD/SD/U12.55.1-825", "vendor": "ABB, Busch-Jaeger", "versions": [{"status": "affected", "version": "1.00", "versionType": "custom"}]}, {"collectionURL": "https://new.abb.com/products/de/2TMA310010B0003/", "defaultStatus": "unaffected", "platforms": ["proprietary"], "product": "2.4! Display 63, SD/U12.63.11-825", "vendor": "ABB, Busch-Jaeger", "versions": [{"status": "affected", "version": "1.00", "versionType": "custom"}]}, {"collectionURL": "https://new.abb.com/products/de/2TMA310011B0003/rt-u12-86-1-825", "defaultStatus": "unaffected", "platforms": ["proprietary"], "product": "RoomTouch 4\", RT/U12.86.1-825", "vendor": "ABB, Busch-Jaeger", "versions": [{"status": "affected", "version": "1.00", "versionType": "custom"}]}, {"collectionURL": "https://new.abb.com/products/de/2TMA310010B0004/rt-u12-86-11-825", "defaultStatus": "unaffected", "product": "RoomTouch 4\", RT/U12.86.11-825", "vendor": "ABB, Busch-Jaeger", "versions": [{"status": "affected", "version": "1.00", "versionType": "custom"}]}, {"collectionURL": "https://new.abb.com/products/de/2TMA310010B0006/sd-u12-70-11-4015", "defaultStatus": "unaffected", "product": "2,4'' Display 70, SD/U12.70.11-4015", "vendor": "ABB, Busch-Jaeger", "versions": [{"status": "affected", "version": "1.00", "versionType": "custom"}]}, {"collectionURL": "https://new.abb.com/products/de/2TMA310011B00004/sd-u12-70-1-4015", "defaultStatus": "unaffected", "product": "2,4'' Display 70, SD-U12-70-1-4015", "vendor": "ABB, Busch-Jaeger", "versions": [{"status": "affected", "version": "1.00", "versionType": "custom"}]}, {"collectionURL": "https://new.abb.com/products/de/2TMA310010W0001/rt-u12-86-11-811", "defaultStatus": "unaffected", "platforms": ["proprietary"], "product": "RoomTouch 4\", RT/U12.86.11-811", "vendor": "ABB, Busch-Jaeger", "versions": [{"status": "affected", "version": "1.00", "versionType": "custom"}]}, {"collectionURL": "https://new.abb.com/products/de/2TMA310011W0001/rt-u12-86-1-811", "defaultStatus": "unaffected", "platforms": ["proprietary"], "product": "RoomTouch 4\", RT-U12-86-1-811", "vendor": "ABB, Busch-Jaeger", "versions": [{"status": "affected", "version": "1.00", "versionType": "custom"}]}, {"collectionURL": "https://new.abb.com/products/de/2CKA006120A0079/ba-u1-0-11", "defaultStatus": "unaffected", "platforms": ["proprietary"], "product": "BCU KNX, BA-U1.0.11", "vendor": "ABB, Busch-Jaeger", "versions": [{"status": "affected", "version": "1.3.0.33", "versionType": "custom"}]}, {"collectionURL": "https://new.abb.com/products/de/2CKA006120A0080/ba-u1-0-1", "defaultStatus": "unaffected", "platforms": ["proprietary"], "product": "BCU KNX, BA-U1.0.1", "vendor": "ABB, Busch-Jaeger", "versions": [{"status": "affected", "version": "1.3.0.33", "versionType": "custom"}]}, {"collectionURL": "https://new.abb.com/products/de/2CKA006120A0081/ba-u1-0-21", "defaultStatus": "unaffected", "platforms": ["proprietary"], "product": "BCU KNX, BA-U1.0.21", "vendor": "ABB, Busch-Jaeger", "versions": [{"status": "affected", "version": "1.3.0.33", "versionType": "custom"}]}], "source": "cybersecurity@ch.abb.com"}], "configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:abb:2tma310010b0001_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2FB4E951-BB1E-49EF-89E1-5FC528E7C39F", "versionEndExcluding": "1.02", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:abb:2tma310010b0001:-:*:*:*:*:*:*:*", "matchCriteriaId": "5887B6A4-F626-43C0-B660-18E9BCB7573A", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:abb:2tma310011b0001_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "47B72D86-BE3B-4E5E-AF78-D15B7BAAFB07", "versionEndExcluding": "1.02", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:abb:2tma310011b0001:-:*:*:*:*:*:*:*", "matchCriteriaId": "FF081477-A638-403C-B964-512AD9D778A1", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:abb:2tma310011b0002_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BF7134CF-B90B-44C5-9AE9-634AD6390C82", "versionEndExcluding": "1.02", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:abb:2tma310011b0002:-:*:*:*:*:*:*:*", "matchCriteriaId": "B2040D08-9289-452C-87A1-0FDE70923797", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:abb:2tma310010b0003_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "90A07BBA-AC3C-43A4-87F5-B7873DE0E83E", "versionEndExcluding": "1.02", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:abb:2tma310010b0003:-:*:*:*:*:*:*:*", "matchCriteriaId": "EAB58037-6EC4-4816-B310-2D8000A1FF74", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:abb:2tma310011b0003_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9125F6EB-0667-47AD-B2EA-F48FF5FE4D63", "versionEndExcluding": "1.02", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:abb:2tma310011b0003:-:*:*:*:*:*:*:*", "matchCriteriaId": "3D74D97B-D726-445F-9E69-9A613D466629", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "cveTags": [], "descriptions": [{"lang": "en", "value": "FDSK Leak in ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to take control via access to local KNX Bus-System"}, {"lang": "es", "value": "La fuga de FDSK en ABB, Busch-Jaeger, FTS Display (versi\u00f3n 1.00) y BCU (versi\u00f3n 1.3.0.33) permite al atacante tomar el control mediante el acceso al sistema de bus KNX local"}], "id": "CVE-2024-4008", "lastModified": "2026-06-17T08:00:55.780", "metrics": {"cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "LOW", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:L/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cybersecurity@ch.abb.com", "type": "Secondary"}, {"cvssData": {"attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}], "cvssMetricV40": [{"cvssData": {"Automatable": "NO", "Recovery": "NOT_DEFINED", "Safety": "NEGLIGIBLE", "attackComplexity": "LOW", "attackRequirements": "PRESENT", "attackVector": "ADJACENT", "availabilityRequirement": "NOT_DEFINED", "baseScore": 7.3, "baseSeverity": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "NONE", "providerUrgency": "GREEN", "subAvailabilityImpact": "HIGH", "subConfidentialityImpact": "LOW", "subIntegrityImpact": "HIGH", "userInteraction": "NONE", "valueDensity": "DIFFUSE", "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:L/VI:H/VA:H/SC:L/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:N/AU:N/R:X/V:D/RE:M/U:Green", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "LOW", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "MODERATE"}, "source": "cybersecurity@ch.abb.com", "type": "Secondary"}], "ssvcV203": [{"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "ssvcData": {"id": "CVE-2024-4008", "options": [{"exploitation": "none"}, {"automatable": "no"}, {"technicalImpact": "partial"}], "role": "CISA Coordinator", "timestamp": "2024-06-10T11:08:58.207948Z", "version": "2.0.3"}}]}, "published": "2024-06-05T18:15:11.113", "references": [{"source": "cybersecurity@ch.abb.com", "tags": ["Vendor Advisory"], "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108464A0803&LanguageCode=en&DocumentPartId=&Action=Launch"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Vendor Advisory"], "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108464A0803&LanguageCode=en&DocumentPartId=&Action=Launch"}], "sourceIdentifier": "cybersecurity@ch.abb.com", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-497"}], "source": "cybersecurity@ch.abb.com", "type": "Secondary"}]}