ZKTeco ZKBio Access IVS Department Name Search Bar cross site scripting
Default status is the baseline for the product, each version can override it (e.g. patched versions marked unaffected).
| Vendor | Product | Default status | Versions | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZKTeco | ZKBio Access IVS | affected |
|
No data.
No data available yet.
| Source | ID | Title |
|---|---|---|
EUVD |
EUVD-2024-17440 | A vulnerability, which was classified as problematic, has been found in ZKTeco ZKBio Access IVS up to 3.3.2. Affected by this issue is some unknown functionality of the component Department Name Search Bar. The manipulation with the input <marquee>hi leads to cross site scripting. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-254396. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |
This CVE is not in the KEV list.
Exploit prediction score: < 1% (0.433% probability within 30 days)
| Type | Values Removed | Values Added |
|---|---|---|
| Metrics |
ssvc
|
| Type | Values Removed | Values Added |
|---|---|---|
| Description | A vulnerability, which was classified as problematic, has been found in ZKTeco ZKBio Access IVS up to 3.3.2. Affected by this issue is some unknown functionality of the component Department Name Search Bar. The manipulation with the input <marquee>hi leads to cross site scripting. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-254396. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | A vulnerability was determined in ZKTeco ZKBio Access IVS up to 3.3.2. This impacts an unknown function of the component Department Name Search Bar. This manipulation with the input <marquee>hi causes cross site scripting. Remote exploitation of the attack is possible. The exploit has been publicly disclosed and may be utilized. The vendor explains: "ZKBio Access IVS is no longer maintained and the product has been replaced by ZKBio CVAccess, it is recommended to replace it with the latest version of ZKBio CVAccess." This vulnerability only affects products that are no longer supported by the maintainer. |
| Weaknesses | CWE-94 | |
| References |
| |
| Metrics |
cvssV2_0
|
cvssV4_0
|
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Zkteco
Zkteco zkbio Access Ivs |
|
| CPEs | cpe:2.3:a:zkteco:zkbio_access_ivs:*:*:*:*:*:*:*:* | |
| Vendors & Products |
Zkteco
Zkteco zkbio Access Ivs |