{"dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": {"cveId": "CVE-2024-1629", "assignerOrgId": "171caf72-b841-4e04-a68e-93493aff2b94", "state": "PUBLISHED", "assignerShortName": "GEHC", "dateReserved": "2024-02-19T15:23:21.436Z", "datePublished": "2024-05-14T16:32:43.530Z", "dateUpdated": "2024-08-01T18:48:21.479Z"}, "containers": {"cna": {"affected": [{"defaultStatus": "unaffected", "product": "Venue", "vendor": "GE HealthCare", "versions": [{"status": "affected", "version": "R1"}, {"status": "affected", "version": "R2"}, {"lessThanOrEqual": "R3.3", "status": "affected", "version": "R3", "versionType": "custom"}, {"lessThanOrEqual": "R4.3", "status": "affected", "version": "R4", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "Venue Go", "vendor": "GE HealthCare", "versions": [{"status": "affected", "version": "R2"}, {"lessThanOrEqual": "R3.3", "status": "affected", "version": "R3", "versionType": "custom"}, {"lessThanOrEqual": "R4.3", "status": "affected", "version": "R4", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "Venue Fit", "vendor": "GE HealthCare", "versions": [{"lessThanOrEqual": "R3.3", "status": "affected", "version": "R3", "versionType": "custom"}, {"lessThanOrEqual": "R4.3", "status": "affected", "version": "R4", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "LOGIQ e", "vendor": "GE HealthCare", "versions": [{"lessThanOrEqual": "R9.1.4", "status": "affected", "version": "R7", "versionType": "custom"}, {"lessThanOrEqual": "R10.1.3", "status": "affected", "version": "R8", "versionType": "custom"}, {"lessThanOrEqual": "R11.0.3", "status": "affected", "version": "R9", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "LOGIQ He", "vendor": "GE HealthCare", "versions": [{"lessThanOrEqual": "R9.3.1", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "Vivid E", "vendor": "GE HealthCare", "versions": [{"lessThan": "206", "status": "affected", "version": "E95", "versionType": "custom"}, {"lessThan": "206", "status": "affected", "version": "E90", "versionType": "custom"}, {"lessThan": "206", "status": "affected", "version": "E80", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "Vivid S", "vendor": "GE HealthCare", "versions": [{"lessThan": "206", "status": "affected", "version": "70N", "versionType": "custom"}, {"lessThan": "206", "status": "affected", "version": "60N", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "Vivid T", "vendor": "GE HealthCare", "versions": [{"lessThan": "206", "status": "affected", "version": "T8", "versionType": "custom"}, {"lessThan": "206", "status": "affected", "version": "T9", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "Vivid iq", "vendor": "GE HealthCare", "versions": [{"lessThan": "206", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "Voluson Expert 16", "vendor": "GE HealthCare", "versions": [{"status": "affected", "version": "0"}, {"status": "affected", "version": "BT24"}]}, {"defaultStatus": "unaffected", "product": "Voluson Expert 18", "vendor": "GE HealthCare", "versions": [{"status": "affected", "version": "0"}, {"status": "affected", "version": "BT24"}]}, {"defaultStatus": "unaffected", "product": "Voluson Expert 22", "vendor": "GE HealthCare", "versions": [{"status": "affected", "version": "0"}, {"status": "affected", "version": "BT24"}]}, {"defaultStatus": "unaffected", "product": "Voluson SWIFT", "vendor": "GE HealthCare", "versions": [{"status": "affected", "version": "0"}, {"status": "affected", "version": "BT24"}]}, {"defaultStatus": "unaffected", "product": "LOGIQ E10", "vendor": "GE HealthCare", "versions": [{"lessThan": "R3.2.0", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "LOGIQ E10s", "vendor": "GE HealthCare", "versions": [{"lessThan": "R3.2.0", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "LOGIQ Fortis", "vendor": "GE HealthCare", "versions": [{"lessThan": "R3.2.0", "status": "affected", "version": "0", "versionType": "custom"}]}], "credits": [{"lang": "en", "type": "finder", "value": "Andrea Palanca and Gabriele Quagliarella of Nozomi Networks"}], "descriptions": [{"lang": "en", "supportingMedia": [{"base64": false, "type": "text/html", "value": "Path traversal vulnerability in \u201cdeleteFiles\u201d function of Common Service Desktop, a GE HealthCare ultrasound device component"}], "value": "Path traversal vulnerability in \u201cdeleteFiles\u201d function of Common Service Desktop, a GE HealthCare ultrasound device component"}], "impacts": [{"capecId": "CAPEC-126", "descriptions": [{"lang": "en", "value": "CAPEC-126 Path Traversal"}]}], "metrics": [{"cvssV3_1": {"attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 6.2, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1"}, "format": "CVSS", "scenarios": [{"lang": "en", "value": "GENERAL"}]}], "problemTypes": [{"descriptions": [{"cweId": "CWE-22", "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')", "lang": "en", "type": "CWE"}]}], "providerMetadata": {"orgId": "171caf72-b841-4e04-a68e-93493aff2b94", "shortName": "GEHC", "dateUpdated": "2024-05-14T16:32:43.530Z"}, "references": [{"url": "https://securityupdate.gehealthcare.com/"}], "source": {"discovery": "EXTERNAL"}, "title": "Path traversal vulnerability in \u201cdeleteFiles\u201d function of Common Service Desktop, a GE HealthCare ultrasound device component", "x_generator": {"engine": "Vulnogram 0.1.0-dev"}}, "adp": [{"title": "CISA ADP Vulnrichment", "metrics": [{"other": {"type": "ssvc", "content": {"id": "CVE-2024-1629", "role": "CISA Coordinator", "options": [{"Exploitation": "none"}, {"Automatable": "no"}, {"Technical Impact": "partial"}], "version": "2.0.3", "timestamp": "2024-05-16T16:09:37.900864Z"}}}], "providerMetadata": {"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2024-06-04T18:01:09.761Z"}}, {"providerMetadata": {"orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-01T18:48:21.479Z"}, "title": "CVE Program Container", "references": [{"url": "https://securityupdate.gehealthcare.com/", "tags": ["x_transferred"]}]}]}}