{"dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": {"cveId": "CVE-2024-1486", "assignerOrgId": "171caf72-b841-4e04-a68e-93493aff2b94", "state": "PUBLISHED", "assignerShortName": "GEHC", "dateReserved": "2024-02-13T22:34:57.386Z", "datePublished": "2024-05-14T15:10:22.262Z", "dateUpdated": "2024-08-16T18:15:02.675Z"}, "containers": {"cna": {"affected": [{"defaultStatus": "unaffected", "product": "Venue", "vendor": "GE HealthCare", "versions": [{"status": "affected", "version": "R1"}, {"status": "affected", "version": "R2"}, {"lessThanOrEqual": "R3.3", "status": "affected", "version": "R3", "versionType": "custom"}, {"lessThanOrEqual": "R4.2", "status": "affected", "version": "R4", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "Venue Go", "vendor": "GE HealthCare", "versions": [{"status": "affected", "version": "R2"}, {"lessThanOrEqual": "R3.3", "status": "affected", "version": "R3", "versionType": "custom"}, {"lessThanOrEqual": "R4.2", "status": "affected", "version": "R4", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "Venue Fit", "vendor": "GE HealthCare", "versions": [{"lessThanOrEqual": "R3.3", "status": "affected", "version": "R3", "versionType": "custom"}, {"lessThanOrEqual": "R4.2", "status": "affected", "version": "R4", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "LOGIQ e", "vendor": "GE HealthCare", "versions": [{"lessThanOrEqual": "R9.1.4", "status": "affected", "version": "R7", "versionType": "custom"}, {"lessThanOrEqual": "R10.1.3", "status": "affected", "version": "R8", "versionType": "custom"}, {"lessThanOrEqual": "R11.0.2", "status": "affected", "version": "R9", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "LOGIQ He", "vendor": "GE HealthCare", "versions": [{"lessThanOrEqual": "R9.3.1", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "Vivid E", "vendor": "GE HealthCare", "versions": [{"lessThan": "206", "status": "affected", "version": "E95", "versionType": "custom"}, {"lessThan": "206", "status": "affected", "version": "E90", "versionType": "custom"}, {"lessThan": "206", "status": "affected", "version": "E80", "versionType": "custom"}, {"lessThanOrEqual": "113.2", "status": "affected", "version": "E9 113.2", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "Vivid S", "vendor": "GE HealthCare", "versions": [{"lessThan": "206", "status": "affected", "version": "70N", "versionType": "custom"}, {"lessThan": "206", "status": "affected", "version": "60N", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "Vivid T", "vendor": "GE HealthCare", "versions": [{"lessThan": "206", "status": "affected", "version": "T8", "versionType": "custom"}, {"lessThan": "206", "status": "affected", "version": "T9", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "Vivid iq", "vendor": "GE HealthCare", "versions": [{"lessThan": "206", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unaffected", "product": "Invenia ABUS", "vendor": "GE HealthCare", "versions": [{"status": "affected", "version": "1.2.3"}]}, {"defaultStatus": "unaffected", "product": "Invenia ABUS 2.0", "vendor": "GE HealthCare", "versions": [{"lessThan": "2.2.9", "status": "affected", "version": "0", "versionType": "custom"}]}], "credits": [{"lang": "en", "type": "finder", "value": "Andrea Palanca and Gabriele Quagliarella of Nozomi Networks"}], "descriptions": [{"lang": "en", "supportingMedia": [{"base64": false, "type": "text/html", "value": "Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices"}], "value": "Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices"}], "impacts": [{"capecId": "CAPEC-1", "descriptions": [{"lang": "en", "value": "CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs"}]}], "metrics": [{"cvssV3_1": {"attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1"}, "format": "CVSS", "scenarios": [{"lang": "en", "value": "GENERAL"}]}], "problemTypes": [{"descriptions": [{"cweId": "CWE-732", "description": "CWE-732 Incorrect Permission Assignment for Critical Resource", "lang": "en", "type": "CWE"}]}], "providerMetadata": {"orgId": "171caf72-b841-4e04-a68e-93493aff2b94", "shortName": "GEHC", "dateUpdated": "2024-05-14T15:10:22.262Z"}, "references": [{"url": "https://securityupdate.gehealthcare.com/"}], "source": {"discovery": "EXTERNAL"}, "title": "Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices", "x_generator": {"engine": "Vulnogram 0.1.0-dev"}}, "adp": [{"providerMetadata": {"orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-01T18:40:21.121Z"}, "title": "CVE Program Container", "references": [{"url": "https://securityupdate.gehealthcare.com/", "tags": ["x_transferred"]}]}, {"affected": [{"vendor": "gehealthcare", "product": "venue_firmware", "cpes": ["cpe:2.3:o:gehealthcare:venue_firmware:*:*:*:*:*:*:*:*"], "defaultStatus": "unaffected", "versions": [{"version": "R1", "status": "affected"}, {"version": "R2", "status": "affected"}, {"version": "R3", "status": "affected", "lessThanOrEqual": "R3.3", "versionType": "custom"}, {"version": "R4", "status": "affected", "lessThanOrEqual": "R4.2", "versionType": "custom"}]}, {"vendor": "gehealthcare", "product": "venue_go_firmware", "cpes": ["cpe:2.3:o:gehealthcare:venue_go_firmware:*:*:*:*:*:*:*:*"], "defaultStatus": "unaffected", "versions": [{"version": "R2", "status": "affected"}, {"version": "R3", "status": "affected", "lessThanOrEqual": "R3.3", "versionType": "custom"}, {"version": "R4", "status": "affected", "lessThanOrEqual": "R4.2", "versionType": "custom"}]}, {"vendor": "gehealthcare", "product": "venue_fit_firmware", "cpes": ["cpe:2.3:o:gehealthcare:venue_fit_firmware:*:*:*:*:*:*:*:*"], "defaultStatus": "unaffected", "versions": [{"version": "R3", "status": "affected", "lessThanOrEqual": "R3.3", "versionType": "custom"}, {"version": "R4", "status": "affected", "lessThanOrEqual": "R4.2", "versionType": "custom"}]}, {"vendor": "gehealthcare", "product": "logiq_e_firmware", "cpes": ["cpe:2.3:o:gehealthcare:logiq_e_firmware:*:*:*:*:*:*:*:*"], "defaultStatus": "unaffected", "versions": [{"version": "R7", "status": "affected", "lessThanOrEqual": "R9.1.4", "versionType": "custom"}, {"version": "R8", "status": "affected", "lessThanOrEqual": "R10.1.3", "versionType": "custom"}, {"version": "R9", "status": "affected", "lessThanOrEqual": "R11.0.2", "versionType": "custom"}]}, {"vendor": "gehealthcare", "product": "logiq_he_firmware", "cpes": ["cpe:2.3:o:gehealthcare:logiq_he_firmware:*:*:*:*:*:*:*:*"], "defaultStatus": "unaffected", "versions": [{"version": "0", "status": "affected", "lessThanOrEqual": "R9.3.1", "versionType": "custom"}]}, {"vendor": "gehealthcare", "product": "vivid_e_firmware", "cpes": ["cpe:2.3:o:gehealthcare:vivid_e_firmware:*:*:*:*:*:*:*:*"], "defaultStatus": "unaffected", "versions": [{"version": "E95", "status": "affected", "lessThan": "206", "versionType": "custom"}, {"version": "E90", "status": "affected", "lessThan": "206", "versionType": "custom"}, {"version": "E80", "status": "affected", "lessThan": "206", "versionType": "custom"}, {"version": "E9 113.2", "status": "affected", "lessThanOrEqual": "113.2", "versionType": "custom"}]}, {"vendor": "gehealthcare", "product": "vivid_s_firmware", "cpes": ["cpe:2.3:o:gehealthcare:vivid_s_firmware:*:*:*:*:*:*:*:*"], "defaultStatus": "unaffected", "versions": [{"version": "70N", "status": "affected", "lessThan": "206", "versionType": "custom"}, {"version": "60N", "status": "affected", "lessThan": "206", "versionType": "custom"}]}, {"vendor": "gehealthcare", "product": "vivid_t_firmware", "cpes": ["cpe:2.3:o:gehealthcare:vivid_t_firmware:*:*:*:*:*:*:*:*"], "defaultStatus": "unaffected", "versions": [{"version": "T8", "status": "affected", "lessThan": "206", "versionType": "custom"}, {"version": "T9", "status": "affected", "lessThan": "206", "versionType": "custom"}]}, {"vendor": "gehealthcare", "product": "vivid_iq_firmware", "cpes": ["cpe:2.3:o:gehealthcare:vivid_iq_firmware:*:*:*:*:*:*:*:*"], "defaultStatus": "unaffected", "versions": [{"version": "0", "status": "affected", "lessThan": "206", "versionType": "custom"}]}, {"vendor": "gehealthcare", "product": "invenia_abus_firmware", "cpes": ["cpe:2.3:o:gehealthcare:invenia_abus_firmware:*:*:*:*:*:*:*:*"], "defaultStatus": "unaffected", "versions": [{"version": "1.2.3", "status": "affected"}]}, {"vendor": "gehealthcare", "product": "invenia_abus_2.0_firmware", "cpes": ["cpe:2.3:o:gehealthcare:invenia_abus_2.0_firmware:*:*:*:*:*:*:*:*"], "defaultStatus": "unaffected", "versions": [{"version": "0", "status": "affected", "lessThan": "2.2.9", "versionType": "custom"}]}], "metrics": [{"other": {"type": "ssvc", "content": {"timestamp": "2024-06-12T14:08:59.014421Z", "id": "CVE-2024-1486", "options": [{"Exploitation": "none"}, {"Automatable": "no"}, {"Technical Impact": "total"}], "role": "CISA Coordinator", "version": "2.0.3"}}}], "title": "CISA ADP Vulnrichment", "providerMetadata": {"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2024-08-16T18:15:02.675Z"}}]}}