SICK InspectorP61x, SICK InspectorP62x and SICK TiM3xx are vulnerable for remote code execution
Default status is the baseline for the product, each version can override it (e.g. patched versions marked unaffected).
| Vendor | Product | Default status | Versions | ||||||
|---|---|---|---|---|---|---|---|---|---|
| SICK AG | SICK InspectorP61x | unaffected |
|
||||||
| SICK AG | SICK InspectorP62x | unaffected |
|
||||||
| SICK AG | TiM3xx | unaffected |
|
||||||
| SICK AG | TDC-X401GL | affected |
|
No data.
No data.
No data available yet.
Vendor Solution
For InspectorP61x and InspectorP62x: Customers are strongly recommended to upgrade to the latest release.
Vendor Workaround
For TiM3xx: We recommend updating the firmware only in a trusted environment.
| Source | ID | Title |
|---|---|---|
EUVD |
EUVD-2024-33529 | Due to missing input validation during one step of the firmware update process, the product is vulnerable to remote code execution. With network access and the user level ”Service”, an attacker can execute arbitrary system commands in the root user’s contexts. |
No CVSS v4.0
No CVSS v3.0
No CVSS v2
This CVE is not in the KEV list.
Exploit prediction score: 1.1% (1.105% probability within 30 days)
| Type | Values Removed | Values Added |
|---|---|---|
| Metrics |
epss
|
epss
|
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Sick
Sick inspector61x Firmware Sick inspector62x Firmware Sick tim3xx |
|
| CPEs | cpe:2.3:a:sick:tim3xx:*:*:*:*:*:*:*:* cpe:2.3:o:sick:inspector61x_firmware:-:*:*:*:*:*:*:* cpe:2.3:o:sick:inspector62x_firmware:-:*:*:*:*:*:*:* |
|
| Vendors & Products |
Sick
Sick inspector61x Firmware Sick inspector62x Firmware Sick tim3xx |
|
| Metrics |
ssvc
|
| Type | Values Removed | Values Added |
|---|---|---|
| Description | Due to missing input validation during one step of the firmware update process, the product is vulnerable to remote code execution. With network access and the user level ”Service”, an attacker can execute arbitrary system commands in the root user’s contexts. | |
| Title | SICK InspectorP61x, SICK InspectorP62x and SICK TiM3xx are vulnerable for remote code execution | |
| Weaknesses | CWE-94 | |
| References |
|
|
| Metrics |
cvssV3_1
|