CVE-2023-7311

BYTEVALUE Intelligent Flow Control Router Command Injection

Published Oct 15, 2025 CVSS 4.0 · 9.3 Critical EPSS 1.9% KEV · Not listed
Description
BYTEVALUE Intelligent Flow Control Router contains a command injection vulnerability via the /goform/webRead/open endpoint. The `path` parameter is not properly validated and is echoed into a shell context, allowing an attacker to inject and execute arbitrary shell commands on the device. Successful exploitation can lead to writing backdoors, privilege escalation on the host, and full compromise of the router and its management functions. VulnCheck has observed this vulnerability being targeted by the RondoDox botnet campaign.

Remediation

No solution or workaround provided in the CVE record

Tracking

Sign in to view the affected projects.

Advisories

No advisories available
History
Type Values Removed Values Added
First Time appeared Bytevalue
Bytevalue flow Control Router
Vendors & Products Bytevalue
Bytevalue flow Control Router
Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'yes', 'Exploitation': 'poc', 'Technical Impact': 'total'}, 'version': '2.0.3'}

Type Values Removed Values Added
Description BYTEVALUE Intelligent Flow Control Router contains a command injection vulnerability via the /goform/webRead/open endpoint. The `path` parameter is not properly validated and is echoed into a shell context, allowing an attacker to inject and execute arbitrary shell commands on the device. Successful exploitation can lead to writing backdoors, privilege escalation on the host, and full compromise of the router and its management functions. VulnCheck has observed this vulnerability being targeted by the Rondo botnet. BYTEVALUE Intelligent Flow Control Router contains a command injection vulnerability via the /goform/webRead/open endpoint. The `path` parameter is not properly validated and is echoed into a shell context, allowing an attacker to inject and execute arbitrary shell commands on the device. Successful exploitation can lead to writing backdoors, privilege escalation on the host, and full compromise of the router and its management functions. VulnCheck has observed this vulnerability being targeted by the RondoDox botnet campaign.
Type Values Removed Values Added
Description BYTEVALUE Intelligent Flow Control Router contains a command injection vulnerability via the /goform/webRead/open endpoint. The `path` parameter is not properly validated and is echoed into a shell context, allowing an attacker to inject and execute arbitrary shell commands on the device. Successful exploitation can lead to writing backdoors, privilege escalation on the host, and full compromise of the router and its management functions. VulnCheck has observed this vulnerability being targeted by the Rondo botnet.
Title BYTEVALUE Intelligent Flow Control Router Command Injection
Weaknesses CWE-78
References
Metrics cvssV4_0

{'score': 9.3, 'vector': 'CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N'}

Weaknesses

Sources

Status
PUBLISHED
Assigner
VulnCheck
Published
Updated
Oct 15, 2025, 8:04 PM
Reserved
Oct 14, 2025, 8:19 PM
Status
Deferred
Published
Oct 15, 2025, 2:15 AM
Modified
Jun 17, 2026, 6:52 AM