{"affected": [{"affectedData": [{"product": "ctrlX HMI Web Panel - WR21 (WR2107)", "vendor": "Rexroth", "versions": [{"status": "affected", "version": "all"}]}, {"product": "ctrlX HMI Web Panel - WR21 (WR2110)", "vendor": "Rexroth", "versions": [{"status": "affected", "version": "all"}]}, {"product": "ctrlX HMI Web Panel - WR21 (WR2115)", "vendor": "Rexroth", "versions": [{"status": "affected", "version": "all"}]}], "source": "psirt@bosch.com"}, {"affectedData": [{"cpes": ["cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*"], "defaultStatus": "unknown", "product": "ctrlx_hmi_web_panel_wr2107", "vendor": "boschrexroth", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"cpes": ["cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2110:-:*:*:*:*:*:*:*"], "defaultStatus": "unknown", "product": "ctrlx_hmi_web_panel_wr2110", "vendor": "boschrexroth", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}, {"cpes": ["cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2115:-:*:*:*:*:*:*:*"], "defaultStatus": "unknown", "product": "ctrlx_hmi_web_panel_wr2115", "vendor": "boschrexroth", "versions": [{"lessThan": "*", "status": "affected", "version": "0", "versionType": "custom"}]}], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"}], "configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2107_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7FFA1309-DBEE-46F1-B6FD-DAE896180411", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*", "matchCriteriaId": "87C129B8-F100-4D3A-97BC-BAD9A4129F9D", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2110_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD47D2E3-F53F-4CE8-BEF7-76F78AEBAF5C", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2110:-:*:*:*:*:*:*:*", "matchCriteriaId": "326E80AA-C9B4-4BF1-AA2B-98A3802A72C9", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2115_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4CA92486-EEBE-42FD-9755-006B7F2DF361", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2115:-:*:*:*:*:*:*:*", "matchCriteriaId": "167C9BC4-FCC5-4FAF-8F75-F967C77400A7", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "cveTags": [], "descriptions": [{"lang": "en", "value": "The vulnerability allows an unprivileged (untrusted) third- party application to arbitrary modify the server settings of the Android Client application, inducing it to connect to an attacker - controlled malicious server.This is possible by forging a valid broadcast intent encrypted with a hardcoded RSA key pair"}, {"lang": "es", "value": "La vulnerabilidad permite que una aplicaci\u00f3n de terceros sin privilegios (no confiable) modifique arbitrariamente la configuraci\u00f3n del servidor de la aplicaci\u00f3n cliente de Android, induci\u00e9ndola a conectarse a un servidor malicioso controlado por un atacante. Esto es posible falsificando una intenci\u00f3n de transmisi\u00f3n v\u00e1lida cifrada con un par de claves RSA codificadas"}], "id": "CVE-2023-41372", "lastModified": "2026-06-17T06:22:02.167", "metrics": {"cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "psirt@bosch.com", "type": "Secondary"}, {"cvssData": {"attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}], "ssvcV203": [{"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "ssvcData": {"id": "CVE-2023-41372", "options": [{"exploitation": "none"}, {"automatable": "no"}, {"technicalImpact": "total"}], "role": "CISA Coordinator", "timestamp": "2024-09-10T18:51:52.995688Z", "version": "2.0.3"}}]}, "published": "2023-10-25T18:17:30.917", "references": [{"source": "psirt@bosch.com", "tags": ["Mitigation", "Vendor Advisory"], "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Mitigation", "Vendor Advisory"], "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"}], "sourceIdentifier": "psirt@bosch.com", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-798"}], "source": "psirt@bosch.com", "type": "Secondary"}, {"description": [{"lang": "en", "value": "CWE-798"}], "source": "nvd@nist.gov", "type": "Primary"}]}