Description

The JMX Console within the Rockwell Automation Pavilion8 is exposed to application users and does not require authentication. If exploited, a malicious user could potentially retrieve other application users’ session data and or log users out of their session.

Remediation

Vendor Solution

Risk Mitigation & User Action Customers using the affected software are encouraged to apply the risk mitigations, if possible. Additionally, we encourage customers to implement our suggested security best practices to minimize the risk of vulnerability. * Update to v5.20 * QA43240 - Recommended Security Guidelines from Rockwell Automation https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012 If customers are unable to update to v5.20, please follow the instructions below to disable the vulnerability in v5.17. * Open the web.xml file in your Pavilion8® installation folder set during installation and go to Console\container\webapps\ROOT\WEB-INF, by default this would be under C:\Pavilion\Console\container\webapps\ROOT\WEB-INF. * Search for the text jmx-console-action-handler and delete the below lines from web.xml file:   <servlet>     <servlet-name>jmx-console-action-handler</servlet-name>     <servlet-class>com.pav.jboss.jmx.HtmlAdaptorServlet</servlet-class>   </servlet>   <servlet-mapping>     <servlet-name>jmx-console-action-handler</servlet-name>     <url-pattern>/jmx-console/HtmlAdaptor</url-pattern>   </servlet-mapping>   * Save the changes and close the file. * Restart Pavilion8® Console Service. * Logout and log back into the console and navigate to the URL http:// <FQDN>/jmx-console to confirm you are getting the error message HTTP Status 404 – Not Found. Note: <FQDN> is your fully qualified domain name used for the Console login.

Tracking

Sign in to view the affected projects.

Advisories

Source ID Title
EUVD EUVD EUVD-2023-33032 The JMX Console within the Rockwell Automation Pavilion8 is exposed to application users and does not require authentication. If exploited, a malicious user could potentially retrieve other application users’ session data and or log users out of their session.
History
Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'none', 'Technical Impact': 'total'}, 'version': '2.0.3'}

Weaknesses

Sources

Status
PUBLISHED
Assigner
Rockwell
Published
Updated
Feb 27, 2025, 8:54 PM
Reserved
Apr 6, 2023, 6:42 PM
Status
Modified
Published
Sep 12, 2023, 5:15 PM
Modified
Jun 17, 2026, 5:50 AM