Default status is the baseline for the product, each version can override it (e.g. patched versions marked unaffected).
| Vendor | Product | Default status | Versions | ||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | Totally Integrated Automation Portal (TIA Portal) V15 | unknown |
|
||||||
| Siemens | Totally Integrated Automation Portal (TIA Portal) V16 | unknown |
|
||||||
| Siemens | Totally Integrated Automation Portal (TIA Portal) V17 | unknown |
|
||||||
| Siemens | Totally Integrated Automation Portal (TIA Portal) V18 | unknown |
|
Configuration 1 [-]
|
No data.
No data available yet.
| Source | ID | Title |
|---|---|---|
EUVD |
EUVD-2023-30116 | A vulnerability has been identified in Totally Integrated Automation Portal (TIA Portal) V15 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions < V16 Update 7), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 6), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 1). Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution. |
No CVSS v4.0
No CVSS v3.0
No CVSS v2
This CVE is not in the KEV list.
Exploit prediction score: < 1% (0.249% probability within 30 days)
| Type | Values Removed | Values Added |
|---|---|---|
| Metrics |
ssvc
|
| Type | Values Removed | Values Added |
|---|---|---|
| Description | A vulnerability has been identified in Totally Integrated Automation Portal (TIA Portal) V15 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 6), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 1). Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution. | A vulnerability has been identified in Totally Integrated Automation Portal (TIA Portal) V15 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions < V16 Update 7), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 6), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 1). Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution. |
| References |
|