CVE-2023-1709

Datalogics Library APDFL Stack-based Buffer Overflow

Published Jun 7, 2023 CVSS 3.1 · 5.5 Medium EPSS < 1% KEV · Not listed
Description

Datalogics Library APDFLThe v18.0.4PlusP1e and prior contains a stack-based buffer overflow due to documents containing corrupted fonts, which could allow an attack that causes an unhandled crash during the rendering process.



Remediation

Vendor Solution

Siemens has released updates for the affected products and recommends updating to the latest versions: * JT2Go: Update to V14.2.0.2 https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html or later version * Teamcenter Visualization V13.2: Update to V13.2.0.13 https://support.sw.siemens.com/   or later version * Teamcenter Visualization V13.3: Update to V13.3.0.9 https://support.sw.siemens.com/   or later version * Teamcenter Visualization V14.0: Update to V14.0.0.5 https://support.sw.siemens.com/   or later version * Teamcenter Visualization V14.1: Update to V14.1.0.7 https://support.sw.siemens.com/   or later version * Teamcenter Visualization V14.2: Update to V14.2.0.2 https://support.sw.siemens.com/   or later version


Vendor Workaround

Siemens has identified the following specific workarounds and mitigations that users can apply to reduce risks: * Avoid opening untrusted files in JT2Go and Teamcenter Visualization As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security https://www.siemens.com/cert/operational-guidelines-industrial-security , and to follow the recommendations in the product manuals. Additional information on industrial security by Siemens can be found at the Siemens Industrial Security web page https://www.siemens.com/industrialsecurity . For further inquiries on security vulnerabilities in Siemens products and solutions, users should contact the Siemens ProductCERT https://www.siemens.com/cert/advisories .

Tracking

Sign in to view the affected projects.

Advisories

Source ID Title
EUVD EUVD EUVD-2023-23933 Datalogics Library APDFLThe v18.0.4PlusP1e and prior contains a stack-based buffer overflow due to documents containing corrupted fonts, which could allow an attack that causes an unhandled crash during the rendering process.
History
Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'none', 'Technical Impact': 'total'}, 'version': '2.0.3'}

Weaknesses

Sources

Status
PUBLISHED
Assigner
icscert
Published
Updated
Jan 6, 2025, 7:59 PM
Reserved
Mar 29, 2023, 10:59 PM
Status
Modified
Published
Jun 7, 2023, 9:15 PM
Modified
Jun 17, 2026, 5:28 AM