{"affected": [{"affectedData": [{"defaultStatus": "unknown", "product": "JT Open", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V11.2.3.0"}]}, {"defaultStatus": "unknown", "product": "JT Utilities", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V13.2.3.0"}]}, {"defaultStatus": "unknown", "product": "Parasolid V34.0", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V34.0.252"}]}, {"defaultStatus": "unknown", "product": "Parasolid V34.1", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V34.1.242"}]}, {"defaultStatus": "unknown", "product": "Parasolid V35.0", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V35.0.170"}]}, {"defaultStatus": "unknown", "product": "Parasolid V35.1", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V35.1.150"}]}], "source": "productcert@siemens.com"}], "configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:a:siemens:jt_open_toolkit:*:*:*:*:*:*:*:*", "matchCriteriaId": "33C7875E-FA42-4163-9395-B5A06E698328", "versionEndExcluding": "11.2.3.0", "vulnerable": true}, {"criteria": "cpe:2.3:a:siemens:jt_utilities:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300A3A0-744A-4D5A-A1CD-D83A1FE97A0B", "versionEndExcluding": "11.2.3.0", "vulnerable": true}, {"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "matchCriteriaId": "F0D9079D-6138-4602-A982-9BC4ECBC35E7", "versionEndExcluding": "34.0.252", "versionStartIncluding": "34.0", "vulnerable": true}, {"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "matchCriteriaId": "4C486991-A1C0-4815-AAD6-163464D711AA", "versionEndExcluding": "34.1.242", "versionStartIncluding": "34.1", "vulnerable": true}, {"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA2114FD-BB07-4C24-98B1-928A510565BB", "versionEndExcluding": "35.0.170", "versionStartIncluding": "35.0", "vulnerable": true}, {"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "matchCriteriaId": "5C98612B-63DF-473C-AF6E-CF3740356D5B", "versionEndExcluding": "35.1.150", "versionStartIncluding": "35.1", "vulnerable": true}], "negate": false, "operator": "OR"}]}], "cveTags": [], "descriptions": [{"lang": "en", "value": "A vulnerability has been identified in JT Open (All versions < V11.2.3.0), JT Utilities (All versions < V13.2.3.0), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Parasolid V35.1 (All versions < V35.1.150). The affected application contains a stack overflow vulnerability while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process."}, {"lang": "es", "value": "Una vulnerabilidad ha sido identificada en JT Open (Todas las versiones anteriores a V11.2.3.0), JT Utilities (Todas las versiones anteriores a V13.2.3.0), Parasolid V34.0 (Todas las versiones anteriores a V34.0.252), Parasolid V34.1 (Todas las versiones anteriores a V34.1.242), Parasolid V35.0 (Todas las versiones anteriores a V35.0.170), Parasolid V35.1 (Todas las versiones anteriores a V35.1.150). La aplicaci\u00f3n afectada contiene una vulnerabilidad de desbordamiento de pila al analizar archivos JT especialmente manipulados. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual."}], "id": "CVE-2022-47936", "lastModified": "2026-10-23T23:10:00.157", "metrics": {"cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Secondary"}, {"cvssData": {"attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}], "ssvcV203": [{"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "ssvcData": {"id": "CVE-2022-47936", "options": [{"exploitation": "none"}, {"automatable": "no"}, {"technicalImpact": "total"}], "role": "CISA Coordinator", "timestamp": "2025-03-20T20:07:21.772715Z", "version": "2.0.3"}}]}, "published": "2023-02-14T11:15:14.473", "references": [{"source": "productcert@siemens.com", "tags": ["Vendor Advisory"], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836777.pdf"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Vendor Advisory"], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836777.pdf"}], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-121"}], "source": "productcert@siemens.com", "type": "Secondary"}]}