{"affected": [{"affectedData": [{"defaultStatus": "unaffected", "product": "PowerLogic ION9000", "vendor": "Schneider Electric", "versions": [{"status": "affected", "version": "Prior to 4.0.0"}]}, {"defaultStatus": "unaffected", "product": "PowerLogic ION7400", "vendor": "Schneider Electric", "versions": [{"status": "affected", "version": "Prior to 4.0.0"}]}, {"defaultStatus": "unaffected", "product": " PowerLogic PM8000", "vendor": "Schneider Electric", "versions": [{"status": "affected", "version": "Prior to 4.0.0"}]}, {"defaultStatus": "unaffected", "product": "PowerLogic ION8650", "vendor": "Schneider Electric", "versions": [{"status": "affected", "version": "All Versions"}]}, {"defaultStatus": "unaffected", "product": "PowerLogic ION8800", "vendor": "Schneider Electric", "versions": [{"status": "affected", "version": "All Versions"}]}, {"defaultStatus": "unaffected", "product": "Legacy ION products", "vendor": "Schneider Electric", "versions": [{"status": "affected", "version": "All Versions"}]}], "source": "cybersecurity@se.com"}], "configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "50C920E5-0F21-4DBB-9D0E-424F8C1A9B85", "versionEndExcluding": "4.0.0", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6718EAAA-074D-4807-AC2D-DD0A06D397FB", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion7400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E43DFCA4-7ED0-4E61-872A-ECD08659A52B", "versionEndExcluding": "4.0.0", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion7400:-:*:*:*:*:*:*:*", "matchCriteriaId": "C8F28EAA-FC60-4CE0-BD39-DFD3EB88E195", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:powerlogic_pm8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4A560510-3A07-4EBB-8E2D-E473EE9B59C9", "versionEndExcluding": "4.0.0", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:powerlogic_pm8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "B16A7BEC-1BED-4A61-A6C9-BF7DB13B998C", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion8650_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFB1251-11AE-4A77-AB68-26D6B58C8F33", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion8650:-:*:*:*:*:*:*:*", "matchCriteriaId": "FBC3A306-D4F4-4C2A-9D60-DD8F0826AEEC", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion8800_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "D1F09F7B-3FFE-4F3A-B79B-3C6B3B718501", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion8800:-:*:*:*:*:*:*:*", "matchCriteriaId": "46E8E79E-6DA7-4094-9622-3B91D5913493", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "cveTags": [], "descriptions": [{"lang": "en", "value": "\nA CWE-319: Cleartext transmission of sensitive information vulnerability exists that could\ncause disclosure of sensitive information, denial of service, or modification of data if an attacker\nis able to intercept network traffic. \n\n"}], "id": "CVE-2022-46680", "lastModified": "2026-06-17T05:12:11.013", "metrics": {"cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cybersecurity@se.com", "type": "Secondary"}, {"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}], "ssvcV203": [{"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "ssvcData": {"id": "CVE-2022-46680", "options": [{"exploitation": "none"}, {"automatable": "yes"}, {"technicalImpact": "total"}], "role": "CISA Coordinator", "timestamp": "2025-01-21T15:05:13.390998Z", "version": "2.0.3"}}]}, "published": "2023-05-22T14:15:09.433", "references": [{"source": "cybersecurity@se.com", "tags": ["Vendor Advisory"], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-129-03.pdf"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Vendor Advisory"], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-129-03.pdf"}], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-319"}], "source": "cybersecurity@se.com", "type": "Secondary"}]}