{"affected": [{"affectedData": [{"defaultStatus": "unknown", "product": "POWER METER SICAM Q100", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V2.50"}]}, {"defaultStatus": "unknown", "product": "POWER METER SICAM Q100", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V2.50"}]}, {"defaultStatus": "unknown", "product": "POWER METER SICAM Q100", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V2.50"}]}, {"defaultStatus": "unknown", "product": "POWER METER SICAM Q100", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V2.50"}]}, {"defaultStatus": "unknown", "product": "SICAM P850", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P850", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P850", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P850", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P850", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P850", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P850", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P850", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P850", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P850", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P850", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P850", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P850", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P850", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P850", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P850", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P850", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P850", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P855", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P855", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P855", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P855", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P855", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P855", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P855", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P855", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P855", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P855", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P855", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P855", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P855", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P855", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P855", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P855", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P855", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}, {"defaultStatus": "unknown", "product": "SICAM P855", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V3.10"}]}], "source": "productcert@siemens.com"}], "configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:siemens:7kg9501-0aa01-2aa1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "821380FC-8F3A-4437-94FF-FB95D9F187D0", "versionEndExcluding": "2.50", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:siemens:7kg9501-0aa01-2aa1:-:*:*:*:*:*:*:*", "matchCriteriaId": "275E9296-AACA-4F3B-B8FA-D52A59E729DE", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:siemens:7kg9501-0aa31-2aa1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AEE155DF-AB9B-4A85-A845-AF1B51B05833", "versionEndExcluding": "2.50", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:siemens:7kg9501-0aa31-2aa1:-:*:*:*:*:*:*:*", "matchCriteriaId": "DC260D4F-53BD-433C-AE8F-FA2FA47BC921", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "cveTags": [], "descriptions": [{"lang": "en", "value": "A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10), SICAM P855 (All versions < V3.10). Affected devices do not properly validate the RecordType-parameter in requests to the web interface on port 443/tcp. This could allow an authenticated remote attacker to crash the device (followed by an automatic reboot) or to execute arbitrary code on the device."}, {"lang": "es", "value": "Se ha identificado una vulnerabilidad en la familia POWER METER SICAM Q200 (Todas las versiones < V2.70), \nSICAM P850 (Todas las versiones < V3.10), \nSICAM P850 (Todas las versiones < V3.10), \nSICAM P850 (Todas las versiones < V3.10), \nSICAM P850 (todas las versiones < V3.10), \nSICAM P850 (todas las versiones < V3.10), \nSICAM P850 (todas las versiones < V3.10), \nSICAM P850 (todas las versiones < V3.10), \nSICAM P850 (todas las versiones < V3.10), \nSICAM P850 (todas las versiones < V3.10), \nSICAM P850 (todas las versiones < V3.10), \nSICAM P850 (todas las versiones < V3. 10), \nSICAM P850 (todas las versiones < V3.10), \nSICAM P850 (todas las versiones < V3.10), \nSICAM P850 (todas las versiones < V3.10), \nSICAM P850 (todas las versiones < V3.10) , \nSICAM P850 (todas las versiones < V3.10), \nSICAM P850 (todas las versiones < V3.10), \nSICAM P850 (todas las versiones < V3.10), \nSICAM P855 (todas las versiones < V3.10), \nSICAM P855 (todas las versiones < V3.10), \nSICAM P855 (todas las versiones < V3.10), \nSICAM P855 (todas las versiones < V3.10), \nSICAM P855 (todas las versiones < V3.10), \nSICAM P855 ( Todas las versiones < V3.10), \nSICAM P855 (Todas las versiones < V3.10), \nSICAM P855 (Todas las versiones < V3.10), \nSICAM P855 (Todas las versiones < V3.10), \nSICAM P855 (Todas las versiones < V3.10), \nSICAM P855 (Todas las versiones < V3. 10), \nSICAM P855 (todas las versiones < V3.10), \nSICAM P855 (todas las versiones < V3.10), \nSICAM P855 (todas las versiones < V3.10), \nSICAM P855 (todas las versiones < V3.10) , \nSICAM P855 (Todas las versiones < V3.10), \nSICAM P855 (Todas las versiones < V3.10), \nSICAM P855 (Todas las versiones < V3.10). \nLos dispositivos afectados no validan correctamente el par\u00e1metro RecordType en las solicitudes a la interfaz web en el puerto 443/tcp. Esto podr\u00eda permitir que un atacante remoto autenticado bloquee el dispositivo (seguido de un reinicio autom\u00e1tico) o ejecute c\u00f3digo arbitrario en el dispositivo."}], "id": "CVE-2022-43545", "lastModified": "2026-06-17T05:06:48.560", "metrics": {"cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.9, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 3.1, "impactScore": 6.0, "source": "productcert@siemens.com", "type": "Secondary"}, {"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2022-11-08T11:15:12.067", "references": [{"source": "productcert@siemens.com", "tags": ["Mitigation", "Patch", "Vendor Advisory"], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-570294.pdf"}, {"source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-572005.pdf"}, {"source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Mitigation", "Patch", "Vendor Advisory"], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-570294.pdf"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-572005.pdf"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf"}], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-20"}], "source": "productcert@siemens.com", "type": "Secondary"}, {"description": [{"lang": "en", "value": "CWE-20"}], "source": "nvd@nist.gov", "type": "Primary"}]}