Default status is the baseline for the product, each version can override it (e.g. patched versions marked unaffected).
| Vendor | Product | Default status | Versions | ||||||
|---|---|---|---|---|---|---|---|---|---|
| HEIDENHAIN | HEIDENHAIN Controller TNC 640 NC Software | unaffected |
|
Configuration 1 [-]
| AND |
|
No data.
No data available yet.
Vendor Solution
HEIDENHAIN has identified the following specific workarounds and mitigations users can apply to reduce risk: * Block LSV2 and DNC communication using the integrated firewall in the controller's operating system. * Use zone firewalls to isolate and segment the network of the affected devices. * Ask your machinery vendor (running HEIDENHAIN controllers) for updates to a recent software version, where SSH tunneling is standard.
Vendor Workaround
HEIDENHAIN has identified the following specific workarounds and mitigations users can apply to reduce risk: * Block LSV2 and DNC communication using the integrated firewall in the controller's operating system. * Use zone firewalls to isolate and segment the network of the affected devices. * Ask machinery vendor (running HEIDENHAIN controllers) for updates to a recent software version, where SSH tunneling is standard.
| Source | ID | Title |
|---|---|---|
EUVD |
EUVD-2022-44836 | The HEIDENHAIN Controller TNC 640, version 340590 07 SP5, running HEROS 5.08.3 controlling the HARTFORD 5A-65E CNC machine is vulnerable to improper authentication, which may allow an attacker to deny service to the production line, steal sensitive data from the production line, and alter any products created by the production line. |
No CVSS v3.0
No CVSS v2
This CVE is not in the KEV list.
Exploit prediction score: < 1% (0.871% probability within 30 days)
| Type | Values Removed | Values Added |
|---|---|---|
| Metrics |
cvssV3_1
|
cvssV3_1
|
| Type | Values Removed | Values Added |
|---|---|---|
| Description | The HEIDENHAIN Controller TNC 640, version 340590 07 SP5, running HEROS 5.08.3 controlling the HARTFORD 5A-65E CNC machine is vulnerable to improper authentication, which may allow an attacker to deny service to the production line, steal sensitive data from the production line, and alter any products created by the production line. | The HEIDENHAIN Controller TNC 640 NC software Version 340590 07 SP5, is vulnerable to improper authentication in its DNC communication for CNC machines. Authentication is not enabled by default for DNC communication. This vulnerability may allow an attacker to deny service on the production line, steal sensitive data from the production line, and alter any products created by the production line. Note: CNC machines running the TNC 640 controller require DNC to be enabled for DNC communication to be present. |
| Weaknesses | CWE-1188 | |
| References |
| |
| Metrics |
cvssV4_0
|
| Type | Values Removed | Values Added |
|---|---|---|
| Metrics |
ssvc
|