{"affected": [{"affectedData": [{"product": "Parasolid V33.1", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V33.1.262"}]}, {"product": "Parasolid V33.1", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions >= V33.1.262 < V33.1.263"}]}, {"product": "Parasolid V34.0", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V34.0.252"}]}, {"product": "Parasolid V34.1", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V34.1.242"}]}, {"product": "Parasolid V35.0", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V35.0.161"}]}, {"product": "Parasolid V35.0", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions >= V35.0.161 < V35.0.164"}]}, {"product": "Simcenter Femap V2022.1", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V2022.1.3"}]}, {"product": "Simcenter Femap V2022.2", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V2022.2.2"}]}], "source": "productcert@siemens.com"}], "configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*", "matchCriteriaId": "55A01C08-1B67-4D81-8730-9ED534E37F7F", "versionEndExcluding": "2022.1.3", "versionStartIncluding": "2022.1", "vulnerable": true}, {"criteria": "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*", "matchCriteriaId": "7CF06743-FC11-46E1-BD60-D9F6F514E52C", "versionEndExcluding": "2022.2.2", "versionStartIncluding": "2022.2", "vulnerable": true}], "negate": false, "operator": "OR"}]}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "matchCriteriaId": "7A2239AD-07CA-4FE9-AAFC-CE580BD903B2", "versionEndExcluding": "33.1.263", "versionStartIncluding": "33.1", "vulnerable": true}, {"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "matchCriteriaId": "F0D9079D-6138-4602-A982-9BC4ECBC35E7", "versionEndExcluding": "34.0.252", "versionStartIncluding": "34.0", "vulnerable": true}, {"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "matchCriteriaId": "4C486991-A1C0-4815-AAD6-163464D711AA", "versionEndExcluding": "34.1.242", "versionStartIncluding": "34.1", "vulnerable": true}, {"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*", "matchCriteriaId": "E5741DD9-05D9-4F2D-AD1F-9D27D2A4070D", "versionEndExcluding": "35.0.164", "versionStartIncluding": "35.0", "vulnerable": true}], "negate": false, "operator": "OR"}]}], "cveTags": [], "descriptions": [{"lang": "en", "value": "A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17740)"}, {"lang": "es", "value": "Se ha identificado una vulnerabilidad en Parasolid versiones V33.1 (Todas las versiones anteriores a V33.1.262), Parasolid versiones V33.1 (Todas las versiones posteriores a V33.1.262 incluy\u00e9ndola, anteriores a V33.1.263), Parasolid versiones V34.0 (Todas las versiones anteriores a V34.0.252), Parasolid versiones V34.1 (Todas las versiones anteriores a V34. 1.242), Parasolid versiones V35.0 (Todas las versiones anteriores a V35.0.161), Parasolid versiones V35.0 (Todas las versiones posteriores a V35.0.161 incluy\u00e9ndola, anteriores a V35.0.164), Simcenter Femap versiones V2022.1 (Todas las versiones anteriores a V2022.1.3), Simcenter Femap versiones V2022.2 (Todas las versiones anteriores a V2022.2.2). La aplicaci\u00f3n afectada contiene una escritura fuera de l\u00edmites m\u00e1s all\u00e1 del final de un b\u00fafer asignado mientras analiza archivos X_T especialmente dise\u00f1ados. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual. (ZDI-CAN-17740)"}], "id": "CVE-2022-39152", "lastModified": "2026-06-17T04:57:48.537", "metrics": {"cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2022-09-13T10:15:11.823", "references": [{"source": "productcert@siemens.com", "tags": ["Vendor Advisory"], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Vendor Advisory"], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"}], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-787"}], "source": "productcert@siemens.com", "type": "Secondary"}, {"description": [{"lang": "en", "value": "CWE-787"}], "source": "nvd@nist.gov", "type": "Primary"}]}