CVE-2022-3263

Measuresoft ScadaPro Server Improper Access Control

Published Sep 23, 2022 CVSS 3.1 · 7.8 High EPSS < 1% KEV · Not listed
Description
The security descriptor of Measuresoft ScadaPro Server version 6.7 has inconsistent permissions, which could allow a local user with limited privileges to modify the service binary path and start malicious commands with SYSTEM privileges.

Remediation

Vendor Workaround

Measuresoft recommends the following steps to remove full access to the ORCHESTRATOR service: 1. Open a command-line window (CMD) with 'run as administrator' 2. Use the following command to make the permission change to the ORCHESTRATOR service: sc sdset ORCHESTRATOR D:(A;;CCLCSWRPWPDTLOCRRC;;;SY)(A;;CCDCLCSWRPWPDTLOCRSDRCWDWO;;;BA)(A;;CCLCSWLOCRRC;;;IU)(A;;CCLCSWLOCRRC;;;SU) 3. As a low-level user, attempt to shut down the ORCHESTRATOR service: sc stop ORCHESTRATOR. User will be denied. It will no longer be possible to edit the configuration of the service by a low-level user.

Tracking

Sign in to view the affected projects.

Advisories

Source ID Title
EUVD EUVD EUVD-2022-42665 The security descriptor of Measuresoft ScadaPro Server version 6.7 has inconsistent permissions, which could allow a local user with limited privileges to modify the service binary path and start malicious commands with SYSTEM privileges.
History
Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'none', 'Technical Impact': 'total'}, 'version': '2.0.3'}

Weaknesses

Sources

Status
PUBLISHED
Assigner
icscert
Published
Updated
Apr 16, 2025, 5:47 PM
Reserved
Sep 21, 2022, 12:00 AM
Status
Modified
Published
Sep 23, 2022, 7:15 PM
Modified
Jun 17, 2026, 4:59 AM