{"affected": [{"affectedData": [{"product": "C-Bus Network Automation Controller, LSS5500NAC", "vendor": "Schneider Electric", "versions": [{"lessThan": "V1.10.0", "status": "affected", "version": "All", "versionType": "custom"}]}, {"product": "Wiser for C-Bus Automation Controller, LSS5500SHAC", "vendor": "Schneider Electric", "versions": [{"lessThan": "V1.10.0", "status": "affected", "version": "All ", "versionType": "custom"}]}, {"product": "Clipsal C-Bus Network Automation Controller, 5500NAC", "vendor": "Schneider Electric", "versions": [{"lessThan": "V1.10.0", "status": "affected", "version": "All ", "versionType": "custom"}]}, {"product": "Clipsal Wiser for C-Bus Automation Controller, 5500SHAC", "vendor": "Schneider Electric", "versions": [{"lessThan": "V1.10.0", "status": "affected", "version": "All ", "versionType": "custom"}]}, {"product": "SpaceLogic C-Bus Network Automation Controller, 5500NAC2", "vendor": "Schneider Electric", "versions": [{"lessThan": "V1.10.0", "status": "affected", "version": "All", "versionType": "custom"}]}, {"product": "SpaceLogic C-Bus Application Controller, 5500AC2", "vendor": "Schneider Electric", "versions": [{"lessThan": "V1.10.0", "status": "affected", "version": "All", "versionType": "custom"}]}], "source": "cybersecurity@se.com"}], "configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:5500ac2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E7628A67-6DD8-47B7-9112-C130AF0DA9BD", "versionEndExcluding": "1.11.0", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:5500ac2:-:*:*:*:*:*:*:*", "matchCriteriaId": "1E9DDB3B-9342-4729-9EE7-703426B9670C", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:5500nac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD075DCC-90DA-45A1-ADC9-ADD7D984B2F9", "versionEndExcluding": "1.11.0", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:5500nac:-:*:*:*:*:*:*:*", "matchCriteriaId": "CDCFD29E-C66E-41F4-B578-095C08799994", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:5500nac2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E7B729EF-ECCC-41E1-BF89-E2EAB013144F", "versionEndExcluding": "1.11.0", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:5500nac2:-:*:*:*:*:*:*:*", "matchCriteriaId": "BF623989-1FC8-44D5-9B4B-42CDCF31B824", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:5500shac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D414788B-B8B5-41A0-8946-433D7A308F4D", "versionEndExcluding": "1.11.0", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:5500shac:-:*:*:*:*:*:*:*", "matchCriteriaId": "91E6F8C8-BC42-4EA0-B36F-96CCE73B080F", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:lss5500nac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B1F807FA-B4A7-4917-80D9-1D9D3AA96516", "versionEndExcluding": "1.11.0", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:lss5500nac:-:*:*:*:*:*:*:*", "matchCriteriaId": "0844B578-39C4-413F-9CE9-5DA12A02CE8A", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:lss5500shac_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3B231797-8810-4C77-BD0B-0C8A6FBD8C2B", "versionEndExcluding": "1.11.0", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:lss5500shac:-:*:*:*:*:*:*:*", "matchCriteriaId": "0B48CA89-FC26-45D4-91C3-F2BD74DC3FBC", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "cveTags": [], "descriptions": [{"lang": "en", "value": "A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker brute forces the password. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)"}, {"lang": "es", "value": "Existe una vulnerabilidad CWE-521: Requisitos de contrase\u00f1a d\u00e9biles que podr\u00eda permitir a un atacante obtener el control del dispositivo cuando fuerza bruta la contrase\u00f1a. Productos afectados: Controlador de automatizaci\u00f3n de red C-Bus - LSS5500NAC (versiones anteriores a V1.10.0), Wiser para controlador de automatizaci\u00f3n de red C-Bus - LSS5500SHAC (versiones anteriores a V1.10.0), Controlador de automatizaci\u00f3n de red Clipsal C-Bus - 5500NAC (versiones anteriores a V1.10.0), Clipsal Wiser para controlador de automatizaci\u00f3n C-Bus - 5500SHAC (versiones anteriores a V1.10.0), controlador de automatizaci\u00f3n de red SpaceLogic C-Bus - 5500NAC2 (versiones anteriores a V1.10.0), controlador de aplicaciones SpaceLogic C-Bus - 5500AC2 (Versiones anteriores a V1.10.0)"}], "id": "CVE-2022-32513", "lastModified": "2026-06-17T04:47:27.140", "metrics": {"cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "cybersecurity@se.com", "type": "Secondary"}, {"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}], "ssvcV203": [{"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "ssvcData": {"id": "CVE-2022-32513", "options": [{"exploitation": "none"}, {"automatable": "yes"}, {"technicalImpact": "total"}], "role": "CISA Coordinator", "timestamp": "2025-02-05T19:57:08.047448Z", "version": "2.0.3"}}]}, "published": "2023-01-30T23:15:09.927", "references": [{"source": "cybersecurity@se.com", "tags": ["Patch", "Vendor Advisory"], "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-06_C-Bus_Home_Automation_Products_Security_Notification.pdf"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Patch", "Vendor Advisory"], "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-06_C-Bus_Home_Automation_Products_Security_Notification.pdf"}], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-521"}], "source": "cybersecurity@se.com", "type": "Secondary"}]}