{"affected": [{"affectedData": [{"product": "CP-8000 MASTER MODULE WITH I/O -25/+70\u00b0C", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < CPC80 V16.30"}]}, {"product": "CP-8000 MASTER MODULE WITH I/O -40/+70\u00b0C", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < CPC80 V16.30"}]}, {"product": "CP-8021 MASTER MODULE", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < CPC80 V16.30"}]}, {"product": "CP-8022 MASTER MODULE WITH GPRS", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < CPC80 V16.30"}]}], "source": "productcert@siemens.com"}], "configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:siemens:sicam_a8000_cp-8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6A3EDA09-C712-416E-BEE4-B49F867FEB56", "versionEndExcluding": "16.30", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:siemens:sicam_a8000_cp-8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "8DEF18ED-BF87-4CFA-A4BA-3387AC8964B3", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:siemens:sicam_a8000_cp-8021_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "41F8797E-D4EC-4758-B526-35178F304DE1", "versionEndExcluding": "16.30", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:siemens:sicam_a8000_cp-8021:-:*:*:*:*:*:*:*", "matchCriteriaId": "65362A2F-DB6D-4D7F-87B5-10E18EE990F0", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:siemens:sicam_a8000_cp-8022_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1182239D-D513-4C0F-8460-D4BDD6A2373A", "versionEndExcluding": "16.30", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:siemens:sicam_a8000_cp-8022:-:*:*:*:*:*:*:*", "matchCriteriaId": "64D59FE8-03FD-4E5B-B7D2-47F31E98A187", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "cveTags": [], "descriptions": [{"lang": "en", "value": "A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70\u00b0C (All versions < CPC80 V16.30), CP-8000 MASTER MODULE WITH I/O -40/+70\u00b0C (All versions < CPC80 V16.30), CP-8021 MASTER MODULE (All versions < CPC80 V16.30), CP-8022 MASTER MODULE WITH GPRS (All versions < CPC80 V16.30). When using the HTTPS server under specific conditions, affected devices do not properly free resources. This could allow an unauthenticated remote attacker to put the device into a denial of service condition."}, {"lang": "es", "value": "Se ha identificado una vulnerabilidad en el MASTER MODULE CP-8000 CON E/S -25/+70\u00b0C (Todas las versiones anteriores a CPC80 V16.30), MASTER MODULE CP-8000 CON E/S -40/+70\u00b0C (Todas las versiones anteriores a CPC80 V16.30), MASTER MODULE CP-8021 (Todas las versiones anteriores a CPC80 V16.30), MASTER MODULE CP-8022 CON GPRS (Todas las versiones anteriores a CPC80 V16.30). Cuando es usado el servidor HTTPS en condiciones espec\u00edficas, los dispositivos afectados no liberan apropiadamente los recursos. Esto podr\u00eda permitir a un atacante remoto no autenticado poner el dispositivo en una condici\u00f3n de denegaci\u00f3n de servicio"}], "id": "CVE-2022-29884", "lastModified": "2026-06-17T04:40:54.157", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": {"accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.1, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C", "version": "2.0"}, "exploitabilityScore": 8.6, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false}], "cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1"}, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2022-07-12T10:15:10.547", "references": [{"source": "productcert@siemens.com", "tags": ["Patch", "Vendor Advisory"], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491621.pdf"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Patch", "Vendor Advisory"], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491621.pdf"}], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-772"}], "source": "productcert@siemens.com", "type": "Secondary"}, {"description": [{"lang": "en", "value": "CWE-772"}], "source": "nvd@nist.gov", "type": "Primary"}]}