CVE-2022-29834

Published Jul 20, 2022 CVSS 3.1 · 7.5 High EPSS 1.7% KEV · Not listed
Description
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1 allows a remote unauthenticated attacker to access to arbitrary files in the GENESIS64 server or ICONICS suite server and disclose information stored in the files by embedding a malicious URL parameter in the URL of the monitoring screen delivered to the GENESIS64 or ICONICS Suite mobile monitoring application and accessing the monitoring screen.

Remediation

No solution or workaround provided in the CVE record

Tracking

Sign in to view the affected projects.

Advisories

Source ID Title
EUVD EUVD EUVD-2022-34152 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in ICONICS GENESIS64 versions 10.97 to 10.97.1 allows a remote unauthenticated attacker to access to arbitrary files in the GENESIS64 server and disclose information stored in the files by embedding a malicious URL parameter in the URL of the monitoring screen delivered to the GENESIS64 mobile monitoring application and accessing the monitoring screen.
History
Type Values Removed Values Added
Description Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in ICONICS GENESIS64 versions 10.97 to 10.97.1 allows a remote unauthenticated attacker to access to arbitrary files in the GENESIS64 server and disclose information stored in the files by embedding a malicious URL parameter in the URL of the monitoring screen delivered to the GENESIS64 mobile monitoring application and accessing the monitoring screen. Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1 allows a remote unauthenticated attacker to access to arbitrary files in the GENESIS64 server or ICONICS suite server and disclose information stored in the files by embedding a malicious URL parameter in the URL of the monitoring screen delivered to the GENESIS64 or ICONICS Suite mobile monitoring application and accessing the monitoring screen.
References
Weaknesses

Sources

Status
PUBLISHED
Assigner
Mitsubishi
Published
Updated
Jan 9, 2026, 4:54 AM
Reserved
Apr 27, 2022, 12:00 AM
Status
Modified
Published
Jul 20, 2022, 5:15 PM
Modified
Jun 17, 2026, 4:40 AM