{"affected": [{"affectedData": [{"product": "n/a", "vendor": "n/a", "versions": [{"status": "affected", "version": "n/a"}]}], "source": "cve@mitre.org"}, {"affectedData": [{"defaultStatus": "unknown", "product": "RUGGEDCOM APE1808 - BIOS", "vendor": "Siemens", "versions": [{"lessThan": "V1.0.202N", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC Field PG M5", "vendor": "Siemens", "versions": [{"lessThan": "V22.01.10", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC Field PG M6", "vendor": "Siemens", "versions": [{"lessThan": "V26.01.13", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC IPC127E", "vendor": "Siemens", "versions": [{"lessThan": "V27.01.09", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC IPC227G", "vendor": "Siemens", "versions": [{"lessThan": "V28.01.04", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC IPC277G", "vendor": "Siemens", "versions": [{"lessThan": "V28.01.04", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC\u00a0IPC277G PRO", "vendor": "Siemens", "versions": [{"lessThan": "V28.01.04", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC IPC327G", "vendor": "Siemens", "versions": [{"lessThan": "V28.01.04", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC IPC377G", "vendor": "Siemens", "versions": [{"lessThan": "V28.01.04", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC IPC427E", "vendor": "Siemens", "versions": [{"lessThan": "V21.01.17", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC IPC477E", "vendor": "Siemens", "versions": [{"lessThan": "V21.01.17", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC IPC477E PRO", "vendor": "Siemens", "versions": [{"lessThan": "V21.01.17", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC IPC627E", "vendor": "Siemens", "versions": [{"lessThan": "V25.02.12", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC IPC647E", "vendor": "Siemens", "versions": [{"lessThan": "V25.02.12", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC IPC677E", "vendor": "Siemens", "versions": [{"lessThan": "V25.02.12", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC IPC847E", "vendor": "Siemens", "versions": [{"lessThan": "V25.02.12", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIMATIC ITP1000", "vendor": "Siemens", "versions": [{"lessThan": "V23.01.10", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "SIPLUS IPC427E", "vendor": "Siemens", "versions": [{"lessThan": "V21.01.17", "status": "affected", "version": "0", "versionType": "custom"}]}], "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e"}], "configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "D26CDAE4-0D04-4EB2-8A8C-CDEBDF8BA38C", "versionEndExcluding": "5.16.29", "versionStartIncluding": "5.1", "vulnerable": true}], "negate": false, "operator": "OR"}]}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "E0546FD8-0648-46EB-893F-411F869077E5", "versionEndExcluding": "5.26.29", "versionStartIncluding": "5.2", "vulnerable": true}], "negate": false, "operator": "OR"}]}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "89966555-5DD1-4C61-B3B2-7AF7AF7D24D9", "versionEndExcluding": "5.35.29", "versionStartIncluding": "5.3", "vulnerable": true}], "negate": false, "operator": "OR"}]}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "95221F93-8BE6-47E3-BFB4-E7603C320F0D", "versionEndExcluding": "5.08.29", "versionStartIncluding": "5.0", "vulnerable": true}], "negate": false, "operator": "OR"}]}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD4E7284-5376-4853-9C28-77867BCB1446", "versionEndExcluding": "5.43.29", "versionStartIncluding": "5.4", "vulnerable": true}], "negate": false, "operator": "OR"}]}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "matchCriteriaId": "BE5BACC3-58DF-4CD6-A204-565CD002AC77", "versionEndExcluding": "5.51.29", "versionStartIncluding": "5.5", "vulnerable": true}], "negate": false, "operator": "OR"}]}], "cveTags": [], "descriptions": [{"lang": "en", "value": "An issue was discovered in AhciBusDxe in Insyde InsydeH2O with kernel 5.0 before 05.08.41, 5.1 before 05.16.29, 5.2 before 05.26.29, 5.3 before 05.35.29, 5.4 before 05.43.29, and 5.5 before 05.51.29. An SMM callout vulnerability allows an attacker to hijack the execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM."}, {"lang": "es", "value": "Se ha detectado un problema en AhciBusDxe en InsydeH2O con el kernel versi\u00f3n 5.0 anteriores a 05.08.41, versiones 5.1 anteriores a 05.16.29, versiones 5.2 anteriores a 05.26.29, versiones 5.3 anteriores a 05.35.29, versiones 5.4 anteriores a 05.43.29 y versiones 5.5 anteriores a 05.51.29. Una vulnerabilidad en la llamada SMM permite a un atacante secuestrar el flujo de ejecuci\u00f3n del c\u00f3digo que es ejecutado en el modo de administraci\u00f3n del sistema. Una explotaci\u00f3n de este problema podr\u00eda conllevar a una escalada de privilegios al SMM"}], "id": "CVE-2022-24069", "lastModified": "2026-08-11T13:17:24.720", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": {"accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0"}, "exploitabilityScore": 3.9, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false}], "cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 1.5, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2022-02-03T00:15:07.723", "references": [{"source": "cve@mitre.org", "tags": ["Third Party Advisory"], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"}, {"source": "cve@mitre.org", "tags": ["Third Party Advisory"], "url": "https://security.netapp.com/advisory/ntap-20220216-0002/"}, {"source": "cve@mitre.org", "tags": ["Vendor Advisory"], "url": "https://www.insyde.com/security-pledge"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Third Party Advisory"], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Third Party Advisory"], "url": "https://security.netapp.com/advisory/ntap-20220216-0002/"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Vendor Advisory"], "url": "https://www.insyde.com/security-pledge"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://www.kb.cert.org/vuls/id/796611"}, {"source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e", "url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"}], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "NVD-CWE-noinfo"}], "source": "nvd@nist.gov", "type": "Primary"}]}