{"affected": [{"affectedData": [{"product": "CODESYS Control RTE (SL)", "vendor": "CODESYS", "versions": [{"lessThan": "V3.5.17.40", "status": "affected", "version": "V3", "versionType": "custom"}]}, {"product": "CODESYS Control RTE (for Beckhoff CX) SL", "vendor": "CODESYS", "versions": [{"lessThan": "V3.5.17.40", "status": "affected", "version": "V3", "versionType": "custom"}]}, {"product": "CODESYS Control Win (SL)", "vendor": "CODESYS", "versions": [{"lessThan": "V3.5.17.40", "status": "affected", "version": "V3", "versionType": "custom"}]}, {"product": "CODESYS HMI (SL)", "vendor": "CODESYS", "versions": [{"lessThan": "V3.5.17.40", "status": "affected", "version": "V3", "versionType": "custom"}]}, {"product": "CODESYS Development System V3", "vendor": "CODESYS", "versions": [{"lessThan": "V3.5.17.40", "status": "affected", "version": "V3", "versionType": "custom"}]}, {"product": "CODESYS Control Runtime System Toolkit", "vendor": "CODESYS", "versions": [{"lessThan": "V3.5.17.40", "status": "affected", "version": "V3", "versionType": "custom"}]}, {"product": "CODESYS Embedded Target Visu Toolkit", "vendor": "CODESYS", "versions": [{"lessThan": "V3.5.17.40", "status": "affected", "version": "V3", "versionType": "custom"}]}, {"product": "CODESYS Remote Target Visu Toolkit", "vendor": "CODESYS", "versions": [{"lessThan": "V3.5.17.40", "status": "affected", "version": "V3", "versionType": "custom"}]}, {"product": "CODESYS Control for BeagleBone SL", "vendor": "CODESYS", "versions": [{"lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom"}]}, {"product": "CODESYS Control for Beckhoff CX9020 SL", "vendor": "CODESYS", "versions": [{"lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom"}]}, {"product": "CODESYS Control for emPC-A/iMX6 SL", "vendor": "CODESYS", "versions": [{"lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom"}]}, {"product": "CODESYS Control for IOT2000 SL", "vendor": "CODESYS", "versions": [{"lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom"}]}, {"product": "CODESYS Control for Linux SL", "vendor": "CODESYS", "versions": [{"lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom"}]}, {"product": "CODESYS Control for PFC100 SL", "vendor": "CODESYS", "versions": [{"lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom"}]}, {"product": "CODESYS Control for PFC200 SL", "vendor": "CODESYS", "versions": [{"lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom"}]}, {"product": "CODESYS Control for PLCnext SL", "vendor": "CODESYS", "versions": [{"lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom"}]}, {"product": "CODESYS Control for Raspberry Pi SL", "vendor": "CODESYS", "versions": [{"lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom"}]}, {"product": "CODESYS Control for WAGO Touch Panels 600 SL", "vendor": "CODESYS", "versions": [{"lessThan": "V4.5.0.0", "status": "affected", "version": "V4", "versionType": "custom"}]}], "source": "info@cert.vde.com"}], "configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*", "matchCriteriaId": "5C0588BE-2046-48F8-95E9-338FB009E2FA", "versionEndExcluding": "4.5.0.0", "vulnerable": true}, {"criteria": "cpe:2.3:a:codesys:control_for_beckhoff_cx9020:*:*:*:*:*:*:*:*", "matchCriteriaId": "45FF3C0B-9043-4E82-A8F3-95CB79D8DAA1", "versionEndExcluding": "4.5.0.0", "vulnerable": true}, {"criteria": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*", "matchCriteriaId": "4CB8984E-ED1F-4F52-B016-F08C0D085C64", "versionEndExcluding": "4.5.0.0", "vulnerable": true}, {"criteria": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*", "matchCriteriaId": "412EBC80-0D9C-419F-9DC3-E2054A8B93B0", "versionEndExcluding": "4.5.0.0", "vulnerable": true}, {"criteria": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*", "matchCriteriaId": "AB585AB5-D0AC-46DC-9723-A0FEFBFB015C", "versionEndExcluding": "4.5.0.0", "vulnerable": true}, {"criteria": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*", "matchCriteriaId": "4F6E2A1D-0187-4C71-A87D-48B3EC3D99DD", "versionEndExcluding": "4.5.0.0", "vulnerable": true}, {"criteria": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*", "matchCriteriaId": "A78E493B-6D9E-4196-830C-24BCF25D3D44", "versionEndExcluding": "4.5.0.0", "vulnerable": true}, {"criteria": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*", "matchCriteriaId": "F66AAE46-CCF8-46D6-89AD-5A4461FCECE9", "versionEndExcluding": "4.5.0.0", "vulnerable": true}, {"criteria": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*", "matchCriteriaId": "9D5DE9D1-C334-452C-A64B-D74A48017B6D", "versionEndExcluding": "4.5.0.0", "vulnerable": true}, {"criteria": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*", "matchCriteriaId": "AB1C57CE-152A-44AE-98B8-39E310255C8E", "versionEndExcluding": "4.5.0.0", "vulnerable": true}, {"criteria": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*", "matchCriteriaId": "01A94C91-B155-4A5A-9F0B-F7E04F3B23B5", "versionEndExcluding": "3.5.18.0", "vulnerable": true}, {"criteria": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*", "matchCriteriaId": "95BC26CF-75EE-43A2-8A92-E877CAF612F3", "versionEndExcluding": "3.5.18.0", "vulnerable": true}, {"criteria": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*", "matchCriteriaId": "1D85A5BC-ADB6-40E4-9434-B57C99185BBA", "versionEndExcluding": "3.5.18.0", "vulnerable": true}, {"criteria": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*", "matchCriteriaId": "AC013B85-98C0-4EF0-844C-4C75D1D237D9", "versionEndExcluding": "3.5.18.0", "vulnerable": true}, {"criteria": "cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*", "matchCriteriaId": "25737EE6-531E-4241-AA40-856388A2E333", "versionEndExcluding": "3.5.18.0", "versionStartIncluding": "3.0", "vulnerable": true}, {"criteria": "cpe:2.3:a:codesys:embedded_target_visu_toolkit:*:*:*:*:*:*:*:*", "matchCriteriaId": "E9F1B30B-6D52-40B1-ABD3-5164A76F5447", "versionEndExcluding": "3.5.18.0", "vulnerable": true}, {"criteria": "cpe:2.3:a:codesys:hmi_sl:*:*:*:*:*:*:*:*", "matchCriteriaId": "60E8930A-4C6C-41CE-8BA8-97332DC753FF", "versionEndExcluding": "3.5.18.0", "vulnerable": true}, {"criteria": "cpe:2.3:a:codesys:remote_target_visu_toolkit:*:*:*:*:*:*:*:*", "matchCriteriaId": "879A9478-54E4-4B6E-A6DC-6DDE1C5E7745", "versionEndExcluding": "3.5.18.0", "vulnerable": true}], "negate": false, "operator": "OR"}]}], "cveTags": [], "descriptions": [{"lang": "en", "value": "A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products."}, {"lang": "es", "value": "Un atacante remoto y autentificado podr\u00eda utilizar el programa de control del sistema de tiempo de ejecuci\u00f3n CODESYS Control para utilizar la vulnerabilidad con el fin de leer y modificar el/los archivo/s de configuraci\u00f3n de los productos afectados"}], "id": "CVE-2022-22515", "lastModified": "2026-06-17T04:28:30.573", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": {"accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 4.9, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:S/C:P/I:P/A:N", "version": "2.0"}, "exploitabilityScore": 6.8, "impactScore": 4.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false}], "cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N", "version": "3.1"}, "exploitabilityScore": 2.8, "impactScore": 5.2, "source": "info@cert.vde.com", "type": "Secondary"}, {"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N", "version": "3.1"}, "exploitabilityScore": 2.8, "impactScore": 5.2, "source": "nvd@nist.gov", "type": "Secondary"}]}, "published": "2022-04-07T19:15:08.187", "references": [{"source": "info@cert.vde.com", "tags": ["Vendor Advisory"], "url": "https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=17089&token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53&download="}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Vendor Advisory"], "url": "https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=17089&token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53&download="}], "sourceIdentifier": "info@cert.vde.com", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-668"}], "source": "info@cert.vde.com", "type": "Secondary"}]}