Dräger Atlan A350 1.00 <= 1.01 DoS via Medibus Interface
Default status is the baseline for the product, each version can override it (e.g. patched versions marked unaffected).
| Vendor | Product | Default status | Versions | ||||||
|---|---|---|---|---|---|---|---|---|---|
| Dräger | Atlan A350 | unknown |
|
No data.
No data.
| Vendor | Product | Versions | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Draeger | Atlan A350 |
|
No CVSS v3.0
No CVSS v2
This CVE is not in the KEV list.
Exploit prediction score: < 1% (0.241% probability within 30 days)
| Type | Values Removed | Values Added |
|---|---|---|
| References |
|
| Type | Values Removed | Values Added |
|---|---|---|
| References |
|
| Type | Values Removed | Values Added |
|---|---|---|
| Description | Dräger Atlan A350 software versions 1.00 through 1.01 contains an improper input handling vulnerability that allows attackers to cause a denial of service by sending specifically crafted non-Medibus-compliant data through the Medibus interface. Attackers can transmit malformed data to overload the internal processor, gradually disrupting device operation over several hours and causing loss of data transmission, delayed display of real-time curves, and deviation between displayed airway pressure values and screen curves. | Dräger Atlan A350 versions 1.00 up to and including 1.01 contains an improper input handling vulnerability that allows attackers to cause a denial of service by sending specifically crafted non-Medibus-compliant data through the Medibus interface. Attackers can transmit malformed data to overload the internal processor, gradually disrupting device operation over several hours and causing loss of data transmission, delayed display of real-time curves, and deviation between displayed airway pressure values and screen curves. |
| Title | Dräger Atlan A350 1.00-1.01 DoS via Medibus Interface | Dräger Atlan A350 1.00 <= 1.01 DoS via Medibus Interface |
| Type | Values Removed | Values Added |
|---|---|---|
| References |
|
| Type | Values Removed | Values Added |
|---|---|---|
| References |
|
| Type | Values Removed | Values Added |
|---|---|---|
| Metrics |
ssvc
|
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Draeger
Draeger atlan A350 |
|
| Vendors & Products |
Draeger
Draeger atlan A350 |
| Type | Values Removed | Values Added |
|---|---|---|
| Description | Dräger Atlan A350 software versions 1.00 through 1.01 contains an improper input handling vulnerability that allows attackers to cause a denial of service by sending specifically crafted non-Medibus-compliant data through the Medibus interface. Attackers can transmit malformed data to overload the internal processor, gradually disrupting device operation over several hours and causing loss of data transmission, delayed display of real-time curves, and deviation between displayed airway pressure values and screen curves. | |
| Title | Dräger Atlan A350 1.00-1.01 DoS via Medibus Interface | |
| Weaknesses | CWE-1286 | |
| References |
| |
| Metrics |
cvssV3_1
|