{"affected": [{"affectedData": [{"product": "POWER METER SICAM Q100", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V2.41"}]}, {"product": "POWER METER SICAM Q100", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V2.41"}]}, {"product": "POWER METER SICAM Q100", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V2.41"}]}, {"product": "POWER METER SICAM Q100", "vendor": "Siemens", "versions": [{"status": "affected", "version": "All versions < V2.41"}]}], "source": "productcert@siemens.com"}], "configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:siemens:7kg9501-0aa01-2aa1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "96EDF0C8-91BF-48C2-8FDC-C3AFBC8878D0", "versionEndExcluding": "2.41", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:siemens:7kg9501-0aa01-2aa1:-:*:*:*:*:*:*:*", "matchCriteriaId": "275E9296-AACA-4F3B-B8FA-D52A59E729DE", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:siemens:7kg9501-0aa31-0aa1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B100E1D3-4D10-4066-9067-799076DD6643", "versionEndExcluding": "2.41", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:siemens:7kg9501-0aa31-0aa1:-:*:*:*:*:*:*:*", "matchCriteriaId": "B09F87C0-1A7D-43F6-A02F-D808C880FF74", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:siemens:7kg9501-0aa31-2aa1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27616240-C04A-4F45-8A6D-B8044242CF5C", "versionEndExcluding": "2.41", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:siemens:7kg9501-0aa31-2aa1:-:*:*:*:*:*:*:*", "matchCriteriaId": "DC260D4F-53BD-433C-AE8F-FA2FA47BC921", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:siemens:7kg9501-0aa01-0aa1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AD0414B9-4EF2-4486-A2BA-926CD0A1D23A", "versionEndExcluding": "2.41", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:siemens:7kg9501-0aa01-0aa1:-:*:*:*:*:*:*:*", "matchCriteriaId": "632E89F3-80E7-4E2F-A3D3-0A6183F4A444", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "cveTags": [], "descriptions": [{"lang": "en", "value": "A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41). The affected firmware contains a buffer overflow vulnerability in the web application that could allow a remote attacker with engineer or admin priviliges to potentially perform remote code execution."}, {"lang": "es", "value": "Se ha identificado una vulnerabilidad en POWER METER SICAM Q100 (Todas las versiones anteriores a V2.41), POWER METER SICAM Q100 (Todas las versiones anteriores a V2.41), POWER METER SICAM Q100 (Todas las versiones anteriores a V2.41), POWER METER SICAM Q100 (Todas las versiones anteriores a V2.41). El firmware afectado contiene una vulnerabilidad de desbordamiento de b\u00fafer en la aplicaci\u00f3n web que podr\u00eda permitir a un atacante remoto con privilegios de ingeniero o administrador realizar potencialmente una ejecuci\u00f3n de c\u00f3digo remota"}], "id": "CVE-2021-44165", "lastModified": "2026-06-17T04:11:58.987", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": {"accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0"}, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false}], "cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1"}, "exploitabilityScore": 1.2, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2021-12-14T12:15:10.923", "references": [{"source": "productcert@siemens.com", "tags": ["Vendor Advisory"], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-496292.pdf"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Vendor Advisory"], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-496292.pdf"}], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-121"}], "source": "productcert@siemens.com", "type": "Secondary"}]}