Carinal Tien Hospital Health Report System - Authorization Bypass Through User-Controlled Key

Published Dec 29, 2021 CVSS 3.1 · 7.3 High EPSS 1.1% KEV · Not listed
Description
Carinal Tien Hospital Health Report System’s login page has improper authentication, a remote attacker can acquire another general user’s privilege by modifying the cookie parameter without authentication. The attacker can then perform limited operations on the system or modify data, making the service partially unavailable to the user.

Remediation

No solution or workaround provided in the CVE record

Tracking

Sign in to view the affected projects.

Advisories

Source ID Title
EUVD EUVD EUVD-2021-31010 Carinal Tien Hospital Health Report System’s login page has improper authentication, a remote attacker can acquire another general user’s privilege by modifying the cookie parameter without authentication. The attacker can then perform limited operations on the system or modify data, making the service partially unavailable to the user.
History

No history.

Weaknesses

Sources

Status
PUBLISHED
Assigner
twcert
Published
Updated
Sep 16, 2024, 11:15 PM
Reserved
Nov 23, 2021, 12:00 AM
Status
Modified
Published
Dec 29, 2021, 8:15 AM
Modified
Jun 17, 2026, 4:11 AM