Remote Code execution
Default status is the baseline for the product, each version can override it (e.g. patched versions marked unaffected).
| Vendor | Product | Default status | Versions | ||||||
|---|---|---|---|---|---|---|---|---|---|
| Eaton | Intelligent Power manager (IPM) | affected |
|
No data.
No data available yet.
Vendor Solution
upgrade the software to latest version 1.69
Vendor Workaround
To prevent the exploitation of the issues and safeguard the software from malicious entities, Eaton recommends blocking ports 4679 & 4680 at the enterprise network or home network where Intelligent Power Manager (IPM) software is installed and used
| Source | ID | Title |
|---|---|---|
EUVD |
EUVD-2021-10376 | Eaton Intelligent Power Manager (IPM) prior to 1.69 is vulnerable to unauthenticated remote code execution vulnerability. IPM software does not sanitize the date provided via coverterCheckList action in meta_driver_srv.js class. Attackers can send a specially crafted packet to make IPM connect to rouge SNMP server and execute attacker-controlled code. |
No CVSS v4.0
No CVSS v3.0
This CVE is not in the KEV list.
Exploit prediction score: 2.3% (2.314% probability within 30 days)
Key SSVC decision points have not yet been added.
No history.