{"affected": [{"affectedData": [{"defaultStatus": "unaffected", "product": "PowerLogic PM55xx, PowerLogic EGX100, and PowerLogic EGX300 (see security notification for version infromation)", "vendor": "n/a", "versions": [{"status": "affected", "version": "PowerLogic PM55xx, PowerLogic EGX100, and PowerLogic EGX300 (see security notification for version infromation)"}]}], "source": "cybersecurity@se.com"}], "configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:powerlogic_pm5560_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0F8EC9ED-1E27-40B8-84A8-F66BC9FD0803", "versionEndExcluding": "2.7.8", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:powerlogic_pm5560:-:*:*:*:*:*:*:*", "matchCriteriaId": "6DDB1B76-3862-462E-B55D-875EBE508B92", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:powerlogic_pm5561_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE3EFC50-39EA-4029-9713-9D191357DD29", "versionEndExcluding": "10.7.3", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:powerlogic_pm5561:-:*:*:*:*:*:*:*", "matchCriteriaId": "00D6C9E0-7DB3-4742-86F0-3430E99D1B1D", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:powerlogic_pm5562_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDBB46A2-4EAD-41DA-AC02-5E985EB755A1", "versionEndIncluding": "2.5.4", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:powerlogic_pm5562:-:*:*:*:*:*:*:*", "matchCriteriaId": "55D7896E-3EFA-4632-B0D2-273084D56936", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}, {"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:schneider-electric:powerlogic_pm5563_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4E870589-0ADF-4B76-89CF-2D36F5C61CF0", "versionEndExcluding": "2.7.8", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:powerlogic_pm5563:-:*:*:*:*:*:*:*", "matchCriteriaId": "C5D4C9C4-C258-453B-85E4-893978D6C499", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "cveTags": [], "descriptions": [{"lang": "en", "value": "A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation) that could cause loss of connectivity to the device via Modbus TCP protocol when an attacker sends a specially crafted HTTP request."}, {"lang": "es", "value": "Un CWE-287: Se presenta una vulnerabilidad de autenticaci\u00f3n inapropiada en PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 y PowerLogic EGX300 (v\u00e9ase la notificaci\u00f3n de seguridad para obtener informaci\u00f3n sobre la versi\u00f3n) que podr\u00eda causar la p\u00e9rdida de conectividad con el dispositivo por medio del protocolo Modbus TCP cuando un atacante env\u00eda una petici\u00f3n HTTP especialmente dise\u00f1ada"}], "id": "CVE-2021-22764", "lastModified": "2026-06-17T03:37:43.843", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": {"accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0"}, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false}], "cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1"}, "exploitabilityScore": 3.9, "impactScore": 1.4, "source": "nvd@nist.gov", "type": "Primary"}, {"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1"}, "exploitabilityScore": 3.9, "impactScore": 1.4, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary"}], "ssvcV203": [{"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "ssvcData": {"id": "CVE-2021-22764", "options": [{"exploitation": "none"}, {"automatable": "yes"}, {"technicalImpact": "partial"}], "role": "CISA Coordinator", "timestamp": "2026-05-29T13:42:20.482218Z", "version": "2.0.3"}}]}, "published": "2021-06-11T16:15:10.390", "references": [{"source": "cybersecurity@se.com", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2021-159-02.pdf"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-02%2Chttp://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-03"}], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-287"}], "source": "cybersecurity@se.com", "type": "Secondary"}]}