CVE-2019-15800

Published Nov 14, 2019 CVSS 3.1 · 9.8 Critical EPSS 3.9% KEV · Not listed
Description
An issue was discovered on Zyxel GS1900 devices with firmware before 2.50(AAHH.0)C0. Due to lack of input validation in the cmd_sys_traceroute_exec(), cmd_sys_arp_clear(), and cmd_sys_ping_exec() functions in the libclicmd.so library contained in the firmware, an attacker could leverage these functions to call system() and execute arbitrary commands on the switches. (Note that these functions are currently not called in this version of the firmware, however an attacker could use other vulnerabilities to finally use these vulnerabilities to gain code execution.)

Remediation

No solution or workaround provided in the CVE record

Tracking

Sign in to view the affected projects.

Advisories

Source ID Title
EUVD EUVD EUVD-2019-6719 An issue was discovered on Zyxel GS1900 devices with firmware before 2.50(AAHH.0)C0. Due to lack of input validation in the cmd_sys_traceroute_exec(), cmd_sys_arp_clear(), and cmd_sys_ping_exec() functions in the libclicmd.so library contained in the firmware, an attacker could leverage these functions to call system() and execute arbitrary commands on the switches. (Note that these functions are currently not called in this version of the firmware, however an attacker could use other vulnerabilities to finally use these vulnerabilities to gain code execution.)
History

No history.