CVE-2017-6034

Schneider Electric Modicon Modbus Protocol Authentication Bypass by Capture-replay

Published Jun 30, 2017 CVSS 3.1 · 9.8 Critical EPSS 5.6% KEV · Not listed
Description
An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download.

Remediation

Vendor Workaround

Schneider Electric has reported that they have introduced compensating controls to limit the exploitability of the identified vulnerabilities in many of the PLCs in the Modicon family; however, Schneider Electric recommends that users apply security measures to improve resiliency. Schneider Electric’s Momentum M1E controllers (all versions of model 171CBU98090 and all versions of model 171CBU98091) do not have built-in compensating controls to limit the exploitability of the identified vulnerabilities and Schneider Electric instructs users to take the following defensive measures: * Protect access to M1E controllers by a firewall blocking all remote/external access to Port 502. Schneider Electric reports that Modicon M340, M580, Premium and Quantum users should take one or more of the following defensive measures: * Enable protection based on an authentication to connect to PLC. This method relies on a feature named Application Password. Once enabled, password-based authentication is required whenever a user connects to change their application program; * Enable protection relying on an input (M340, Premium, Quantum) or a key switch in the front panel (Quantum) to reject remote connection or run/stop commands; and * Enable the “Access Control List protection,” where users are able to configure the restricted IP addresses that are pre-authorized to control the PLC. For additional information, Schneider Electric has released a Cybersecurity Notification, which is available at the following location: https://www.se.com/us/en/download/document/SEVD-2017-065-01/

Tracking

Sign in to view the affected projects.

Advisories

Source ID Title
EUVD EUVD EUVD-2017-15102 An Authentication Bypass by Capture-Replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download.
History
Type Values Removed Values Added
Description An Authentication Bypass by Capture-Replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download. An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download.
Title Schneider Electric Modicon Modbus Protocol Authentication Bypass by Capture-replay
References
Type Values Removed Values Added
Metrics cvssV3_1

{'score': 9.8, 'vector': 'CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H'}

ssvc

{'options': {'Automatable': 'yes', 'Exploitation': 'none', 'Technical Impact': 'total'}, 'version': '2.0.3'}

Weaknesses

Sources

Status
PUBLISHED
Assigner
icscert
Published
Updated