CVE-2017-2342

SRX Series: MACsec failure to report errors

Published Jul 14, 2017 CVSS 3.0 · 8.1 High EPSS < 1% KEV · Not listed
Description
MACsec feature on Juniper Networks Junos OS 15.1X49 prior to 15.1X49-D100 on SRX300 series does not report errors when a secure link can not be established. It falls back to an unencrypted link. This can happen when MACsec is configured on ports that are not capable of MACsec or when a secure link can not be established. This can mislead customers into believing that a link is secure. On SRX 300 series devices, prior to 15.1X49-D100, MACsec was only supported on control and fabric ports of SRX340 and SRX345 devices. SRX300 and and SRX320 did not have any MACsec capable ports. Configuring MACsec on ports that were not MACsec capable would have resulted in this issue. Affected releases are Juniper Networks Junos OS 15.1X49 prior to 15.1X49-D100 on SRX300 series.

Remediation

Vendor Workaround

There are no viable workarounds for this issue. It is good security practice to limit the exploitable attack surface of critical infrastructure networking equipment. Use access lists or firewall filters to limit access to the device from trusted, administrative networks or hosts.

Tracking

Sign in to view the affected projects.

Advisories

Source ID Title
EUVD EUVD EUVD-2017-11525 MACsec feature on Juniper Networks Junos OS 15.1X49 prior to 15.1X49-D100 on SRX300 series does not report errors when a secure link can not be established. It falls back to an unencrypted link. This can happen when MACsec is configured on ports that are not capable of MACsec or when a secure link can not be established. This can mislead customers into believing that a link is secure. On SRX 300 series devices, prior to 15.1X49-D100, MACsec was only supported on control and fabric ports of SRX340 and SRX345 devices. SRX300 and and SRX320 did not have any MACsec capable ports. Configuring MACsec on ports that were not MACsec capable would have resulted in this issue. Affected releases are Juniper Networks Junos OS 15.1X49 prior to 15.1X49-D100 on SRX300 series.
History

No history.

Weaknesses

Sources

Status
PUBLISHED
Assigner
juniper
Published
Updated
Sep 16, 2024, 4:27 PM
Reserved
Dec 1, 2016, 12:00 AM
Status
Modified
Published
Jul 17, 2017, 1:18 PM
Modified
Jun 17, 2026, 1:16 AM