Schneider Electric ETG3000 FactoryCast HMI Gateway Missing Authentication for Critical Function
Default status is the baseline for the product, each version can override it (e.g. patched versions marked unaffected).
| Vendor | Product | Default status | Versions | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | ETG3000 FactoryCast HMI Gateway | unaffected |
|
Configuration 1 [-]
| AND |
|
No data.
No data available yet.
Vendor Solution
Schneider Electric has produced an updated firmware, labelled V1.60 IR 04. This firmware release moves the jar files directory in a secure area. The new firmware also includes the ability to disable the FTP server. This updated firmware can be downloaded at: http://www.schneider-electric.com/download/WW/EN/details/681790255-TSXETG30xx-V160-IR4/?showAsIframe... http://www.schneider-electric.com/download/WW/EN/details/681790255-TSXETG30xx-V160-IR4/
Vendor Workaround
Schneider Electric recommends the FTP server be deactivated when not needed. The firmware update does not remove the hard-coded credentials. Narendra Shinde also found that configuration files were accessible using default credentials. Schneider Electric recommends users change the default login credentials. This will protect configuration files from unauthorized access.
| Source | ID | Title |
|---|---|---|
EUVD |
EUVD-2014-9022 | The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct request. |
No CVSS v4.0
No CVSS v3.1
No CVSS v3.0
This CVE is not in the KEV list.
Exploit prediction score: 2.0% (1.957% probability within 30 days)
Key SSVC decision points have not yet been added.
| Type | Values Removed | Values Added |
|---|---|---|
| Title | Schneider Electric ETG3000 FactoryCast HMI Gateway Missing Authentication for Critical Function | |
| Weaknesses | CWE-306 | |
| References |
| |
| Metrics |
cvssV2_0
|
cvssV2_0
|