Search vulnerabilities

Results 10

Export CSV
CVE-2026-9621

RSLinx Classic® - Multiple Vulnerabilities

A denial-of-service security issue exists within RSLinx® Classic. The security issue stems from improper handling of a malformed packet. A crafted CIP packet can cause the RSLinx® Classic service to crash, requiring a restart of the service to recover

CVSS 4.0 · 9.2 Critical EPSS < 1% KEV · Not listed
CVE-2026-9625

RSLinx Classic® - Multiple Vulnerabilities

A denial-of-service security issue exists within RSLinx® Classic. A crafted CIP packet with an oversized embedded message request can cause the RSLinx® Classic service to crash, requiring a restart of the service to recover.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
CVE-2026-9624

RSLinx Classic® - Multiple Vulnerabilities

A denial-of-service security issue exists within RSLinx® Classic. A crafted CIP packet can cause the RSLinx® Classic service to crash due to insufficient data length validation, requiring a  restart of the service to recover.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
CVE-2020-12005

FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. A vulnerability exists in the communication function that enables users to upload EDS files by FactoryTalk Linx. This may allow an attacker to upload a file with bad compression, consuming all the available CPU resources, leading to a denial-of-service condition.

CVSS 3.1 · 7.5 High EPSS 1.8% KEV · Not listed
CVE-2020-12003

FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to use specially crafted requests to traverse the file system and expose sensitive data on the local hard drive.

CVSS 3.1 · 7.5 High EPSS 5.4% KEV · Not listed
CVE-2020-12001

FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. The parsing mechanism that processes certain file types does not provide input sanitation. This may allow an attacker to use specially crafted files to traverse the file system and modify or expose sensitive data or execute arbitrary code.

CVSS 3.1 · 9.8 Critical EPSS 11.8% KEV · Not listed
CVE-2020-11999

FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to specify a filename to execute unauthorized code and modify files or data.

CVSS 3.1 · 8.1 High EPSS 2.8% KEV · Not listed
CVE-2020-10642

In Rockwell Automation RSLinx Classic versions 4.11.00 and prior, an authenticated local attacker could modify a registry key, which could lead to the execution of malicious code using system privileges when opening RSLinx Classic.

CVSS 3.1 · 7.8 High EPSS < 1% KEV · Not listed
Products
CVE-2018-10619

An unquoted search path or element in RSLinx Classic Versions 3.90.01 and prior and FactoryTalk Linx Gateway Versions 3.90.00 and prior may allow an authorized, but non-privileged local user to execute arbitrary code and allow a threat actor to escalate user privileges on the affected workstation.

CVSS 3.0 · 7.8 High EPSS 2.7% KEV · Not listed