CVE-2020-16228

Philips Patient Monitoring Devices Improper Check for Certificate Revocation

In Patient Information Center iX (PICiX) Versions C.02 and C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and prior, the software does not check or incorrectly checks the revocation status of a certificate, which may cause it to use a compromised certificate.

CVSS 3.1 · 6.4 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2020-16224

Philips Patient Monitoring Devices Improper Handling of Length Parameter Inconsistency

In Patient Information Center iX (PICiX) Versions C.02, C.03, the software parses a formatted message or structure but does not handle or incorrectly handles a length field that is inconsistent with the actual length of the associated data, causing the application on the surveillance station to restart.

CVSS 3.1 · 6.5 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2020-16222

Philips Patient Monitoring Devices Improper Authentication

In Patient Information Center iX (PICiX) Version B.02, C.02, C.03, and PerformanceBridge Focal Point Version A.01, when an actor claims to have a given identity, the software does not prove or insufficiently proves the claim is correct.

CVSS 3.1 · 8.8 High EPSS < 1% KEV · Not listed
Vendors
CVE-2020-16220

Philips Patient Monitoring Devices Improper Validation of Syntactic Correctness of Input

In Patient Information Center iX (PICiX) Versions C.02, C.03, PerformanceBridge Focal Point Version A.01, the product receives input that is expected to be well-formed (i.e., to comply with a certain syntax) but it does not validate or incorrectly validates that the input complies with the syntax, causing the certificate enrollment service to crash. It does not impact monitoring but prevents new devices from enrolling.

CVSS 3.1 · 4.3 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2020-16218

Philips Patient Monitoring Devices Cross-site Scripting

In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is then used as a webpage and served to other users. Successful exploitation could lead to unauthorized access to patient data via a read-only web application.

CVSS 3.1 · 3.5 Low EPSS < 1% KEV · Not listed
Vendors
CVE-2020-16216

Philips Patient Monitoring Devices Improper Input Validation

In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750, MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior, the product receives input or data but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly, which can induce a denial-of-service condition through a system restart.

CVSS 3.1 · 6.5 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2020-16214

Philips Patient Monitoring Devices Improper Neutralization of Formula Elements in a CSV File

In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software saves user-provided information into a comma-separated value (CSV) file, but it does not neutralize or incorrectly neutralizes special elements that could be interpreted as a command when the file is opened by spreadsheet software.

CVSS 3.1 · 5.0 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2021-43552

Philips Patient Information Center iX (PIC iX) and Efficia CM Series Use of Hard-coded Cryptographic Key

The use of a hard-coded cryptographic key significantly increases the possibility encrypted data may be recovered from the Patient Information Center iX (PIC iX) Versions B.02, C.02, and C.03.

CVSS 3.1 · 6.1 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2021-43550

Philips Patient Information Center iX (PIC iX) and Efficia CM Series Use of a Broken or Risky Cryptographic Algorithm

The use of a broken or risky cryptographic algorithm is an unnecessary risk that may result in the exposure of sensitive information, which affects the communications between Patient Information Center iX (PIC iX) Versions C.02 and C.03 and Efficia CM Series Revisions A.01 to C.0x and 4.0.

CVSS 3.1 · 5.9 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2021-43548

Philips Patient Information Center iX (PIC iX) and Efficia CM Series Improper Input Validation

Patient Information Center iX (PIC iX) Versions C.02 and C.03 receives input or data, but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.

CVSS 3.1 · 6.5 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2020-16212

Philips Patient Monitoring Devices Exposure of Resource to Wrong Sphere

In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource. The application on the surveillance station operates in kiosk mode, which is vulnerable to local breakouts that could allow an attacker with physical access to escape the restricted environment with limited privileges.

CVSS 3.1 · 6.8 Medium EPSS < 1% KEV · Not listed
Vendors