CVE-2024-1914

An attacker who successfully exploited these vulnerabilities could cause the robot to stop, make the robot controller inaccessible. The vulnerability could potentially be exploited to perform unauthorized actions by an attacker. This vulnerability arises under specific condition when specially crafted message is processed by the system. Below are reported vulnerabilities in the Robot Ware versions. * IRC5- RobotWare 6 < 6.15.06 except 6.10.10, and 6.13.07 * OmniCore- RobotWare 7 < 7.14

CVSS 3.1 · 6.5 Medium EPSS < 1% KEV · Not listed
Vendors
Abb
Products
CVE-2024-1913

An attacker who successfully exploited these vulnerabilities could cause the robot to stop, make the robot controller inaccessible, or execute arbitrary code.  The vulnerability could potentially be exploited to perform unauthorized actions by an attacker. This vulnerability arises under specific condition when specially crafted message is processed by the system. Below are reported vulnerabilities in the Robot Ware versions. * IRC5- RobotWare 6 < 6.15.06 except 6.10.10, and 6.13.07 * OmniCore- RobotWare 7 < 7.14

CVSS 3.1 · 7.6 High EPSS < 1% KEV · Not listed
Vendors
Abb
Products
CVE-2012-0245

Multiple stack-based buffer overflows in RobNetScanHost.exe in ABB Robot Communications Runtime before 5.14.02, as used in ABB Interlink Module, IRC5 OPC Server, PC SDK, PickMaster 3 and 5, RobView 5, RobotStudio, WebWare SDK, and WebWare Server, allow remote attackers to execute arbitrary code via a crafted (1) 0xA or (2) 0xE Netscan packet.

CVSS 2.0 · 10.0 Critical EPSS 8.1% KEV · Not listed
Vendors
Abb
CVE-2020-10288

RVD#3327: No authentication required for accesing ABB IRC5 FTP server

IRC5 exposes an ftp server (port 21). Upon attempting to gain access you are challenged with a request of username and password, however you can input whatever you like. As long as the field isn't empty it will be accepted.

CVSS 3.1 · 9.8 Critical EPSS 1.4% KEV · Not listed
Vendors
Products
Irb140 Irc5 Robotware and 1 more
CVE-2020-10287

RVD#3326: Hardcoded default credentials on IRC 5 OPC Server

The IRC5 family with UAS service enabled comes by default with credentials that can be found on publicly available manuals. ABB considers this a well documented functionality that helps customer set up however, out of our research, we found multiple production systems running these exact default credentials and consider thereby this an exposure that should be mitigated. Moreover, future deployments should consider that these defaults should be forbidden (user should be forced to change them).

CVSS 3.1 · 9.8 Critical EPSS 1.4% KEV · Not listed