Search vulnerabilities

Results 40

Export CSV
CVE-2026-5045

Tenda FH1201 Parameter WrlclientSet stack-based overflow

A vulnerability was detected in Tenda FH1201 1.2.0.14(408). This impacts the function WrlclientSet of the file /goform/WrlclientSet of the component Parameter Handler. Performing a manipulation of the argument GO results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
CVE-2026-5046

Tenda FH1201 Parameter WrlExtraSet formWrlExtraSet stack-based overflow

A flaw has been found in Tenda FH1201 1.2.0.14(408). Affected is the function formWrlExtraSet of the file /goform/WrlExtraSet of the component Parameter Handler. Executing a manipulation of the argument GO can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been published and may be used.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
CVE-2025-14995

Tenda FH1201 SetIpBind sprintf stack-based overflow

A vulnerability has been found in Tenda FH1201 1.2.0.14(408). Affected is the function sprintf of the file /goform/SetIpBind. Such manipulation of the argument page leads to stack-based buffer overflow. The attack may be performed from remote. The exploit has been disclosed to the public and may be used.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
CVE-2025-14994

Tenda FH1201/FH1206 HTTP Request webtypelibrary strcat stack-based overflow

A flaw has been found in Tenda FH1201 and FH1206 1.2.0.14(408)/1.2.0.8(8155). This impacts the function strcat of the file /goform/webtypelibrary of the component HTTP Request Handler. This manipulation of the argument webSiteId causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been published and may be used.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2025-7548

Tenda FH1201 SafeEmailFilter formSafeEmailFilter stack-based overflow

A vulnerability has been found in Tenda FH1201 1.2.0.14(408) and classified as critical. This vulnerability affects the function formSafeEmailFilter of the file /goform/SafeEmailFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
CVE-2025-7549

Tenda FH1201 L7Prot frmL7ProtForm stack-based overflow

A vulnerability was found in Tenda FH1201 1.2.0.14(408) and classified as critical. This issue affects the function frmL7ProtForm of the file /goform/L7Prot. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
CVE-2025-7550

Tenda FH1201 GstDhcpSetSer fromGstDhcpSetSer stack-based overflow

A vulnerability was found in Tenda FH1201 1.2.0.14(408). It has been classified as critical. Affected is the function fromGstDhcpSetSer of the file /goform/GstDhcpSetSer. The manipulation of the argument dips leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
CVE-2025-7551

Tenda FH1201 PPTPDClient fromPptpUserAdd stack-based overflow

A vulnerability was found in Tenda FH1201 1.2.0.14(408). It has been declared as critical. Affected by this vulnerability is the function fromPptpUserAdd of the file /goform/PPTPDClient. The manipulation of the argument modino/username leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

CVSS 4.0 · 8.7 High EPSS 1.2% KEV · Not listed
Vendors
CVE-2025-7463

Tenda FH1201 HTTP POST Request AdvSetWrlsafeset formWrlsafeset buffer overflow

A vulnerability was found in Tenda FH1201 1.2.0.14. It has been declared as critical. This vulnerability affects the function formWrlsafeset of the file /goform/AdvSetWrlsafeset of the component HTTP POST Request Handler. The manipulation of the argument mit_ssid leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

CVSS 4.0 · 8.7 High EPSS 1.2% KEV · Not listed
Vendors
CVE-2025-7465

Tenda FH1201 HTTP POST Request fromRouteStatic buffer overflow

A vulnerability classified as critical was found in Tenda FH1201 1.2.0.14. Affected by this vulnerability is the function fromRouteStatic of the file /goform/fromRouteStatic of the component HTTP POST Request Handler. The manipulation of the argument page leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
CVE-2025-7468

Tenda FH1201 HTTP POST Request fromSafeUrlFilter buffer overflow

A vulnerability has been found in Tenda FH1201 1.2.0.14 and classified as critical. This vulnerability affects the function fromSafeUrlFilter of the file /goform/fromSafeUrlFilter of the component HTTP POST Request Handler. The manipulation of the argument page leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
CVE-2025-6110

Tenda FH1201 SafeMacFilter stack-based overflow

A vulnerability classified as critical has been found in Tenda FH1201 1.2.0.14(408). This affects an unknown part of the file /goform/SafeMacFilter. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

CVSS 4.0 · 8.7 High EPSS 6.0% KEV · Not listed
Vendors
CVE-2024-42952

Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromqossetting function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
Vendors
CVE-2024-42947

An issue in the handler function in /goform/telnet of Tenda FH1201 v1.2.0.14 (408) allows attackers to execute arbitrary commands via a crafted HTTP request.

CVSS 3.1 · 9.8 Critical EPSS < 1% KEV · Not listed
Vendors
CVE-2024-12002

Tenda FH451/FH1201/FH1202/FH1206 GetIPTV websReadEvent null pointer dereference

A vulnerability classified as problematic was found in Tenda FH451, FH1201, FH1202 and FH1206 up to 20241129. Affected by this vulnerability is the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

CVSS 4.0 · 5.3 Medium EPSS < 1% KEV · Not listed
Vendors
Products