Export limit exceeded: 425824 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search vulnerabilities

Results 2,049

Export CSV
CVE-2026-10192

Tenda W12 httpd set_local_time_0 stack-based overflow

A vulnerability was identified in Tenda W12 3.0.0.7(4763). The affected element is the function set_local_time_0 of the file /bin/httpd. Such manipulation of the argument Time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit is publicly available and might be used.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2026-9389

Tenda F456 L7Im frmL7ImForm buffer overflow

A security vulnerability has been detected in Tenda F456 1.0.0.5. This affects the function frmL7ImForm of the file /goform/L7Im. The manipulation of the argument page leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2026-9428

Tenda F1202 PPTPUserSetting fromPPTPUserSetting stack-based overflow

A vulnerability has been found in Tenda F1202 1.2.0.20(408). Affected is the function fromPPTPUserSetting of the file /goform/PPTPUserSetting. Such manipulation of the argument delno leads to stack-based buffer overflow. The attack may be performed from remote. The exploit has been disclosed to the public and may be used.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
CVE-2026-9430

Tenda F1202 GstDhcpSetSerof formGstDhcpSetSer stack-based overflow

A vulnerability was determined in Tenda F1202 1.2.0.20(408). Affected by this issue is the function formGstDhcpSetSer of the file /goform/GstDhcpSetSerof. Executing a manipulation of the argument dips can lead to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been publicly disclosed and may be utilized.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
CVE-2026-9429

Tenda F1202 WrlExtraSet formWrlExtraSet stack-based overflow

A vulnerability was found in Tenda F1202 1.2.0.20(408). Affected by this vulnerability is the function formWrlExtraSet of the file /goform/WrlExtraSet. Performing a manipulation of the argument delno results in stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been made public and could be used.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
CVE-2026-9431

Tenda F1202 PptpUserAdd fromPptpUserAdd stack-based overflow

A vulnerability was identified in Tenda F1202 1.2.0.20(408). This affects the function fromPptpUserAdd of the file /goform/PptpUserAdd. The manipulation of the argument opttype leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit is publicly available and might be used.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
CVE-2026-8263

Tenda AC6 httpd WifiExtraSet fromSetWirelessRepeat os command injection

A security flaw has been discovered in Tenda AC6 15.03.06.49_multi_TDE01. Affected is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet of the component httpd. Performing a manipulation of the argument mac/ssid results in os command injection. It is possible to initiate the attack remotely. The exploit has been released to the public and may be used for attacks.

CVSS 4.0 · 5.1 Medium EPSS 5.0% KEV · Not listed
Vendors
Products
Ac10u Ac10u Firmware Ac6 and 1 more
CVE-2026-8259

Tenda AC6 httpd telnet os command injection

A vulnerability has been found in Tenda AC6 2.0/15.03.06.23. The affected element is an unknown function of the file /goform/telnet of the component httpd. The manipulation of the argument lan.ip leads to os command injection. Remote exploitation of the attack is possible. The exploit has been disclosed to the public and may be used.

CVSS 4.0 · 5.1 Medium EPSS 4.9% KEV · Not listed
Vendors
Products
CVE-2026-8264

Tenda AC6 httpd WifiApScan formWifiApScan os command injection

A weakness has been identified in Tenda AC6 15.03.06.23. Affected by this vulnerability is the function formWifiApScan of the file /goform/WifiApScan of the component httpd. Executing a manipulation of the argument wl2g.public.country/wl5g.public.country can lead to os command injection. It is possible to launch the attack remotely. The exploit has been made available to the public and could be used for attacks.

CVSS 4.0 · 5.3 Medium EPSS 3.2% KEV · Not listed
Vendors
Products
CVE-2026-8265

Tenda AC6 httpd getLogFile get_log_file os command injection

A security vulnerability has been detected in Tenda AC6 15.03.06.23. Affected by this issue is the function get_log_file of the file /goform/getLogFile of the component httpd. The manipulation of the argument wans.flag leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used.

CVSS 4.0 · 5.1 Medium EPSS 4.8% KEV · Not listed
Vendors
Products
CVE-2026-8138

Tenda CX12L SetPptpServerCfg” formSetPPTPServer stack-based overflow

A vulnerability was found in Tenda CX12L 16.03.53.12. This issue affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg”. The manipulation results in stack-based buffer overflow. The attack can be executed remotely. The exploit has been made public and could be used.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
CVE-2026-7470

Tenda 4G300 SafeMacFilter sub_427C3C stack-based overflow

A flaw has been found in Tenda 4G300 US_4G300V1.0Mt_V1.01.42_CN_TDC01. Affected is the function sub_427C3C of the file /goform/SafeMacFilter. This manipulation of the argument page causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been published and may be used.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
CVE-2026-5604

Tenda CH22 Parameter CertLocalPrecreate formCertLocalPrecreate stack-based overflow

A security flaw has been discovered in Tenda CH22 1.0.0.1. The impacted element is the function formCertLocalPrecreate of the file /goform/CertLocalPrecreate of the component Parameter Handler. Performing a manipulation of the argument standard results in stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been released to the public and may be used for attacks.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2026-5605

Tenda CH22 WrlExtraSet formWrlExtraSet stack-based overflow

A weakness has been identified in Tenda CH22 1.0.0.1. This affects the function formWrlExtraSet of the file /goform/WrlExtraSet. Executing a manipulation of the argument GO can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been made available to the public and could be used for attacks.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2026-7469

Tenda 4G300 DelFil sub_425A28 command injection

A vulnerability was detected in Tenda 4G300 US_4G300V1.0Mt_V1.01.42_CN_TDC01. This impacts the function sub_425A28 of the file /goform/DelFil. The manipulation of the argument delflag results in command injection. The attack may be launched remotely. The exploit is now public and may be used.

CVSS 4.0 · 5.3 Medium EPSS 1.4% KEV · Not listed
Vendors
CVE-2026-5154

Tenda CH22 Parameter setcfm fromSetCfm stack-based overflow

A vulnerability has been found in Tenda CH22 1.0.0.1/1.If. The impacted element is the function fromSetCfm of the file /goform/setcfm of the component Parameter Handler. The manipulation of the argument funcname leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed to the public and may be used.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2026-7160

Tenda HG3 formTracert command injection

A vulnerability was determined in Tenda HG3 2.0. This vulnerability affects the function formTracert of the file /boaform/formTracert. Executing a manipulation of the argument datasize can lead to command injection. The attack may be performed from remote. The exploit has been publicly disclosed and may be utilized.

CVSS 4.0 · 8.7 High EPSS 3.3% KEV · Not listed
Vendors
Products
CVE-2026-7151

Tenda HG3 formIPv6Routing formUploadConfig stack-based overflow

A vulnerability was determined in Tenda HG3 2.0. Impacted is the function formUploadConfig of the file /boaform/formIPv6Routing. This manipulation of the argument destNet causes stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been publicly disclosed and may be utilized.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2026-7119

Tenda HG3 formCountrystr os command injection

A vulnerability was detected in Tenda HG3 2.0. The impacted element is an unknown function of the file /boaform/formCountrystr. The manipulation of the argument countrystr results in os command injection. The attack may be performed from remote. The exploit is now public and may be used.

CVSS 4.0 · 8.7 High EPSS 3.3% KEV · Not listed
Vendors
Products
CVE-2026-7096

Tenda HG3 formgponConf os command injection

A security flaw has been discovered in Tenda HG3 2.0 300003070. This vulnerability affects the function formgponConf of the file /boaform/admin/formgponConf. The manipulation of the argument fmgpon_loid results in os command injection. It is possible to launch the attack remotely. The exploit has been released to the public and may be used for attacks.

CVSS 4.0 · 8.7 High EPSS 4.1% KEV · Not listed
Vendors
Products