Search vulnerabilities

Results 2,049

Export CSV
CVE-2023-38936

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.

CVSS 3.1 · 9.8 Critical EPSS < 1% KEV · Not listed
Vendors
Products
Ac10 Ac10 Firmware Ac1206 and 15 more
CVE-2023-38935

Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function.

CVSS 3.1 · 9.8 Critical EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2023-38934

Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName function.

CVSS 3.1 · 9.8 Critical EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2023-38933

Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function.

CVSS 3.1 · 9.8 Critical EPSS < 1% KEV · Not listed
Vendors
Products
Ac10 Ac10 Firmware Ac1206 and 15 more
CVE-2023-38932

Tenda F1202 V1.2.0.9, PA202 V1.1.2.5, PW201A V1.1.2.5 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the page parameter in the SafeEmailFilter function.

CVSS 3.1 · 9.8 Critical EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2023-38931

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function.

CVSS 3.1 · 9.8 Critical EPSS < 1% KEV · Not listed
Vendors
Products
Ac10 Ac10 Firmware Ac1206 and 13 more
CVE-2023-38930

Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function.

CVSS 3.1 · 9.8 Critical EPSS < 1% KEV · Not listed
Vendors
Products
Ac5 Ac5 Firmware Ac7 and 7 more
CVE-2023-38929

Tenda 4G300 v1.01.42 was discovered to contain a stack overflow via the page parameter at /VirtualSer.

CVSS 3.1 · 9.8 Critical EPSS < 1% KEV · Not listed
Vendors
CVE-2023-37723

Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromqossetting.

CVSS 3.1 · 9.8 Critical EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2023-37722

Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeUrlFilter.

CVSS 3.1 · 9.8 Critical EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2023-37721

Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeMacFilter.

CVSS 3.1 · 9.8 Critical EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2023-37719

Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromP2pListFilter.

CVSS 3.1 · 9.8 Critical EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2023-37718

Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeClientFilter.

CVSS 3.1 · 9.8 Critical EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2023-37717

Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient.

CVSS 3.1 · 9.8 Critical EPSS < 1% KEV · Not listed
Vendors
Products
Ac10 Ac10 Firmware Ac1206 and 11 more
CVE-2023-37716

Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting.

CVSS 3.1 · 9.8 Critical EPSS < 1% KEV · Not listed
Vendors
Products
Ac10 Ac10 Firmware Ac1206 and 11 more
CVE-2023-37715

Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function frmL7ProtForm.

CVSS 3.1 · 9.8 Critical EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2023-37714

Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromRouteStatic.

CVSS 3.1 · 9.8 Critical EPSS < 1% KEV · Not listed
Vendors
Products
Ac7 Ac7 Firmware F1202 and 5 more
CVE-2023-37711

Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the deviceId parameter in the saveParentControlInfo function.

CVSS 3.1 · 9.8 Critical EPSS 1.2% KEV · Not listed
Vendors
Products
CVE-2023-37710

Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the wpapsk_crypto parameter in the fromSetWirelessRepeat function.

CVSS 3.1 · 9.8 Critical EPSS 1.2% KEV · Not listed
Vendors
Products
CVE-2023-37707

Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the page parameter in the fromVirtualSer function.

CVSS 3.1 · 9.8 Critical EPSS 1.1% KEV · Not listed
Vendors