Search vulnerabilities

Results 2,049

Export CSV
CVE-2024-40416

A vulnerability in /goform/SetVirtualServerCfg in the sub_6320C function in Tenda AX1806 1.0.0.1 firmware leads to stack-based buffer overflow.

CVSS 3.1 · 6.5 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2024-40415

A vulnerability in /goform/SetStaticRouteCfg in the sub_519F4 function in Tenda AX1806 1.0.0.1 firmware leads to stack-based buffer overflow.

CVSS 3.1 · 9.8 Critical EPSS < 1% KEV · Not listed
Vendors
CVE-2024-40414

A vulnerability in /goform/SetNetControlList in the sub_656BC function in Tenda AX1806 1.0.0.1 firmware leads to stack-based buffer overflow.

CVSS 3.1 · 9.6 Critical EPSS < 1% KEV · Not listed
Vendors
CVE-2024-33180

Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId parameter at ip/goform/saveParentControlInfo.

CVSS 3.1 · 9.8 Critical EPSS < 1% KEV · Not listed
Vendors
CVE-2024-30621

Tenda AX1803 v1.0.0.1 contains a stack overflow via the serverName parameter in the function fromAdvSetMacMtuWan.

CVSS 3.1 · 9.8 Critical EPSS < 1% KEV · Not listed
Vendors
CVE-2024-2856

Tenda AC10 SetSysTimeCfg fromSetSysTime stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda AC10 16.03.10.13/16.03.10.20. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257780. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS 3.1 · 8.8 High EPSS 1.2% KEV · Not listed
Vendors
Products
CVE-2024-2855

Tenda AC15 SetSysTimeCfg fromSetSysTime stack-based overflow

A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.05.19/15.03.20. Affected by this vulnerability is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257779. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS 3.1 · 8.8 High EPSS 1.3% KEV · Not listed
Vendors
Products
CVE-2024-2854

Tenda AC18 setsambacfg formSetSambaConf os command injection

A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257778 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS 3.1 · 6.3 Medium EPSS 3.9% KEV · Not listed
Vendors
Products
CVE-2024-2853

Tenda AC10U setsambacfg formSetSambaConf os command injection

A vulnerability was found in Tenda AC10U 15.03.06.48/15.03.06.49. It has been rated as critical. This issue affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257777 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS 3.1 · 6.3 Medium EPSS 4.0% KEV · Not listed
Vendors
CVE-2024-2852

Tenda AC15 saveParentControlInfo stack-based overflow

A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257776. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS 3.1 · 8.8 High EPSS 1.3% KEV · Not listed
Vendors
Products
CVE-2024-2851

Tenda AC15 setsambacfg formSetSambaConf os command injection

A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been classified as critical. This affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257775. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS 3.1 · 6.3 Medium EPSS 4.0% KEV · Not listed
Vendors
Products
CVE-2024-2850

Tenda AC15 saveParentControlInfo stack-based overflow

A vulnerability was found in Tenda AC15 15.03.05.18 and classified as critical. Affected by this issue is the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257774 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS 3.1 · 8.8 High EPSS 1.3% KEV · Not listed
Vendors
Products