CVE-2018-10613

Multiple variants of XML External Entity (XXE) attacks may be used to exfiltrate data from the host Windows platform in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior.

CVSS 3.0 · 7.5 High EPSS 17.5% KEV · Not listed
Vendors
Ge
Products
CVE-2018-10611

Java remote method invocation (RMI) input port in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior may be exploited to allow unauthenticated users to launch applications and support remote code execution through web services.

CVSS 3.0 · 9.8 Critical EPSS 4.8% KEV · Not listed
Vendors
Ge
Products
CVE-2017-7908

A heap-based buffer overflow exists in the third-party product Gigasoft, v5 and prior, included in GE Communicator 3.15 and prior. A malicious HTML file that loads the ActiveX controls can trigger the vulnerability via unchecked function calls.

CVSS 3.0 · 7.6 High EPSS < 1% KEV · Not listed
Vendors
CVE-2017-14008

GE Centricity PACS RA1000, diagnostic image analysis, all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.

CVSS 3.0 · 9.8 Critical EPSS 3.0% KEV · Not listed
Vendors
Ge
CVE-2017-14006

GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are affected, these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.

CVSS 3.0 · 9.8 Critical EPSS 1.9% KEV · Not listed
Vendors
Ge
Products
CVE-2017-14004

GE GEMNet License server (EchoServer) all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.

CVSS 3.0 · 9.8 Critical EPSS 1.9% KEV · Not listed
Vendors
Ge
CVE-2017-14002

GE Infinia/Infinia with Hawkeye 4 medical imaging systems all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.

CVSS 3.0 · 9.8 Critical EPSS 4.7% KEV · Not listed
Vendors
Ge
CVE-2012-6663

General Electric D20ME devices are not properly configured and reveal plaintext passwords.

CVSS 3.1 · 7.5 High EPSS 9.5% KEV · Not listed
Vendors
Ge
Products
D200 D200 Firmware D20me and 1 more