Search vulnerabilities

Results 1,814

Export CSV
CVE-2026-2157

D-Link DIR-823X set_static_route_table sub_4175CC os command injection

A security vulnerability has been detected in D-Link DIR-823X 250416. This affects the function sub_4175CC of the file /goform/set_static_route_table. Such manipulation of the argument interface/destip/netmask/gateway/metric leads to os command injection. The attack may be performed from remote. The exploit has been disclosed publicly and may be used.

CVSS 4.0 · 8.6 High EPSS 4.7% KEV · Not listed
Vendors
CVE-2026-2854

D-Link DWR-M960 NTP Configuration Endpoint formNtp sub_4611CC stack-based overflow

A flaw has been found in D-Link DWR-M960 1.01.07. This impacts the function sub_4611CC of the file /boafrm/formNtp of the component NTP Configuration Endpoint. Executing a manipulation of the argument submit-url can lead to stack-based buffer overflow. The attack can be launched remotely. The exploit has been published and may be used.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
CVE-2026-1506

D-Link DIR-615 MAC Filter Configuration adv_mac_filter.php os command injection

A vulnerability was determined in D-Link DIR-615 4.10. Impacted is an unknown function of the file /adv_mac_filter.php of the component MAC Filter Configuration. This manipulation of the argument mac causes os command injection. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized. This vulnerability only affects products that are no longer supported by the maintainer.

CVSS 4.0 · 8.6 High EPSS 5.6% KEV · Not listed
Vendors
CVE-2026-2056

D-Link DIR-605L/DIR-619L DHCP Connection Status wan_connection_status.asp information disclosure

A security vulnerability has been detected in D-Link DIR-605L and DIR-619L 2.06B01/2.13B01. The impacted element is an unknown function of the file /wan_connection_status.asp of the component DHCP Connection Status Handler. The manipulation leads to information disclosure. Remote exploitation of the attack is possible. The exploit has been disclosed publicly and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

CVSS 4.0 · 6.9 Medium EPSS 1.1% KEV · Not listed
Vendors
Products
CVE-2026-2061

D-Link DIR-823X set_ipv6 sub_424D20 os command injection

A vulnerability was determined in D-Link DIR-823X 250416. Affected by this issue is the function sub_424D20 of the file /goform/set_ipv6. Executing a manipulation can lead to os command injection. It is possible to launch the attack remotely. The exploit has been publicly disclosed and may be utilized.

CVSS 4.0 · 5.1 Medium EPSS 5.1% KEV · Not listed
Vendors
CVE-2026-2084

D-Link DIR-823X set_language os command injection

A weakness has been identified in D-Link DIR-823X 250416. This impacts an unknown function of the file /goform/set_language. Executing a manipulation of the argument langSelection can lead to os command injection. It is possible to launch the attack remotely. The exploit has been made available to the public and could be used for attacks.

CVSS 4.0 · 8.6 High EPSS 4.6% KEV · Not listed
Vendors
CVE-2026-2085

D-Link DWR-M921 USSD Configuration Endpoint formUSSDSetup sub_419F20 command injection

A security vulnerability has been detected in D-Link DWR-M921 1.1.50. Affected is the function sub_419F20 of the file /boafrm/formUSSDSetup of the component USSD Configuration Endpoint. The manipulation of the argument ussdValue leads to command injection. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used.

CVSS 4.0 · 8.6 High EPSS 10.5% KEV · Not listed
Vendors
CVE-2026-2152

D-Link DIR-615 Web Configuration adv_routing.php os command injection

A vulnerability was found in D-Link DIR-615 4.10. This vulnerability affects unknown code of the file adv_routing.php of the component Web Configuration Interface. Performing a manipulation of the argument dest_ip/ submask/ gw results in os command injection. The attack may be initiated remotely. The exploit has been made public and could be used. This vulnerability only affects products that are no longer supported by the maintainer.

CVSS 4.0 · 8.6 High EPSS 5.4% KEV · Not listed
Vendors
CVE-2026-2218

D-Link DCS-933L alphapd setSystemAdmin command injection

A vulnerability was determined in D-Link DCS-933L up to 1.14.11. This affects an unknown function of the file /setSystemAdmin of the component alphapd. This manipulation of the argument AdminID causes command injection. Remote exploitation of the attack is possible. The exploit has been publicly disclosed and may be utilized. This vulnerability only affects products that are no longer supported by the maintainer.

CVSS 4.0 · 5.3 Medium EPSS 4.4% KEV · Not listed
Vendors
CVE-2026-2227

D-Link DCS-931L setSystemAdmin doSystem command injection

A vulnerability was found in D-Link DCS-931L up to 1.13.0. Impacted is the function doSystem of the file /setSystemAdmin. Performing a manipulation of the argument AdminID results in command injection. The attack may be initiated remotely. The exploit has been made public and could be used. This vulnerability only affects products that are no longer supported by the maintainer.

CVSS 4.0 · 5.1 Medium EPSS 6.8% KEV · Not listed
Vendors
CVE-2026-2857

D-Link DWR-M960 Port Forwarding Configuration Endpoint formPortFw sub_423E00 stack-based overflow

A vulnerability was determined in D-Link DWR-M960 1.01.07. Affected by this issue is the function sub_423E00 of the file /boafrm/formPortFw of the component Port Forwarding Configuration Endpoint. This manipulation of the argument submit-url causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been publicly disclosed and may be utilized.

CVSS 4.0 · 8.7 High EPSS 1.0% KEV · Not listed
Vendors
CVE-2026-2881

D-Link DWR-M960 Advanced Firewall Configuration Endpoint formFirewallAdv sub_425FF8 stack-based overflow

A vulnerability has been found in D-Link DWR-M960 1.01.07. This vulnerability affects the function sub_425FF8 of the file /boafrm/formFirewallAdv of the component Advanced Firewall Configuration Endpoint. Such manipulation of the argument submit-url leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
CVE-2026-2882

D-Link DWR-M960 formDosCfg sub_46385C stack-based overflow

A vulnerability was found in D-Link DWR-M960 1.01.07. This issue affects the function sub_46385C of the file /boafrm/formDosCfg. Performing a manipulation of the argument submit-url results in stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made public and could be used.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
CVE-2026-2884

D-Link DWR-M960 WAN Interface Setting formWanConfigSetup sub_41914C stack-based overflow

A vulnerability was identified in D-Link DWR-M960 1.01.07. The affected element is the function sub_41914C of the file /boafrm/formWanConfigSetup of the component WAN Interface Setting Handler. The manipulation of the argument submit-url leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is publicly available and might be used.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
CVE-2026-2962

D-Link DWR-M960 Scheduled Reboot Configuration Endpoint formDateReboot sub_460F30 stack-based overflow

A vulnerability was found in D-Link DWR-M960 1.01.07. This vulnerability affects the function sub_460F30 of the file /boafrm/formDateReboot of the component Scheduled Reboot Configuration Endpoint. The manipulation of the argument submit-url results in stack-based buffer overflow. The attack may be performed from remote. The exploit has been made public and could be used.

CVSS 4.0 · 8.7 High EPSS 4.1% KEV · Not listed
Vendors
CVE-2026-0732

D-Link DI-8200G upgrade_filter.asp command injection

A vulnerability was found in D-Link DI-8200G 17.12.20A1. This affects an unknown function of the file /upgrade_filter.asp. The manipulation of the argument path results in command injection. The attack may be performed from remote. The exploit has been made public and could be used.

CVSS 4.0 · 5.3 Medium EPSS 11.7% KEV · Not listed
Vendors
CVE-2026-1125

D-Link DIR-823X set_wifidog_settings sub_412E7C command injection

A weakness has been identified in D-Link DIR-823X 250416. Affected by this issue is the function sub_412E7C of the file /goform/set_wifidog_settings. Executing a manipulation of the argument wd_enable can lead to command injection. The attack can be executed remotely. The exploit has been made available to the public and could be used for attacks.

CVSS 4.0 · 6.9 Medium EPSS 15.7% KEV · Not listed
Vendors
CVE-2026-23755

D-Link D-View 8 Installer DLL Preloading via Uncontrolled Search Path

D-Link D-View 8 versions 2.0.1.107 and below contain an uncontrolled search path vulnerability in the installer. When executed with elevated privileges via UAC, the installer attempts to load version.dll from its execution directory, allowing DLL preloading. An attacker can supply a malicious version.dll alongside the legitimate installer so that, when a victim runs the installer and approves the UAC prompt, attacker-controlled code executes with administrator privileges. This can lead to full system compromise.

CVSS 4.0 · 8.4 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2026-23754

D-Link D-View 8 IDOR Allows Credential Disclosure and Account Takeover

D-Link D-View 8 versions 2.0.1.107 and below contain an improper access control vulnerability in backend API endpoints. Any authenticated user can supply an arbitrary user_id value to retrieve sensitive credential data belonging to other users, including super administrators. The exposed credential material can be reused directly as a valid authentication secret, allowing full impersonation of the targeted account. This results in complete account takeover and full administrative control over the D-View system.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2026-1419

D-Link DCS700l Web Form setDayNightMode command injection

A weakness has been identified in D-Link DCS700l 1.03.09. Affected is an unknown function of the file /setDayNightMode of the component Web Form Handler. Executing a manipulation of the argument LightSensorControl can lead to command injection. The attack may be launched remotely. The exploit has been made available to the public and could be used for attacks.

CVSS 4.0 · 5.1 Medium EPSS 17.2% KEV · Not listed
Vendors