Search vulnerabilities

Results 128

Export CSV
CVE-2020-16240

GE Digital APM Classic, Versions 4.4 and prior. An insecure direct object reference (IDOR) vulnerability allows user account data to be downloaded in JavaScript object notation (JSON) format by users who should not have access to such functionality. An attacker can download sensitive data related to user accounts without having the proper privileges.

CVSS 3.1 · 5.3 Medium EPSS < 1% KEV · Not listed
Vendors
Ge
CVE-2020-12017

GE Grid Solutions Reason RT Clocks, RT430, RT431, and RT434, all firmware versions prior to 08A05. The device’s vulnerability in the web application could allow multiple unauthenticated attacks that could cause serious impact. The vulnerability may allow an unauthenticated attacker to execute arbitrary commands and send a request to a specific URL that could cause the device to become unresponsive. The unauthenticated attacker may change the password of the 'configuration' user account, allowing the attacker to modify the configuration of the device via the web interface using the new password. This vulnerability may also allow an unauthenticated attacker to bypass the authentication required to configure the device and reboot the system.

CVSS 3.1 · 9.8 Critical EPSS 2.3% KEV · Not listed
Vendors
Ge
Products
CVE-2019-6566

GE Communicator, all versions prior to 4.0.517, allows a non-administrative user to replace the uninstaller with a malicious version, which could allow an attacker to gain administrator privileges to the system.

CVSS 3.1 · 7.8 High EPSS < 1% KEV · Not listed
Vendors
Ge
Products
CVE-2019-6564

GE Communicator, all versions prior to 4.0.517, allows a non-administrative user to place malicious files within the installer file directory, which may allow an attacker to gain administrative privileges on a system during installation or upgrade.

CVSS 3.1 · 7.8 High EPSS < 1% KEV · Not listed
Vendors
Ge
Products
CVE-2019-6548

GE Communicator, all versions prior to 4.0.517, contains two backdoor accounts with hardcoded credentials, which may allow control over the database. This service is inaccessible to attackers if Windows default firewall settings are used by the end user.

CVSS 3.1 · 9.8 Critical EPSS 1.3% KEV · Not listed
Vendors
Ge
Products
CVE-2019-6546

GE Communicator, all versions prior to 4.0.517, allows an attacker to place malicious files within the working directory of the program, which may allow an attacker to manipulate widgets and UI elements.

CVSS 3.1 · 7.8 High EPSS < 1% KEV · Not listed
Vendors
Ge
Products
CVE-2019-6544

GE Communicator, all versions prior to 4.0.517, has a service running with system privileges that may allow an unprivileged user to perform certain administrative actions, which may allow the execution of scheduled scripts with system administrator privileges. This service is inaccessible to attackers if Windows default firewall settings are used by the end user.

CVSS 3.1 · 5.6 Medium EPSS 1.2% KEV · Not listed
Vendors
Ge
Products
CVE-2019-18267

An issue was found in GE S2020/S2020G Fast Switch 61850, S2020/S2020G Fast Switch 61850 Versions 07A03 and prior. An attacker can inject arbitrary Javascript in a specially crafted HTTP request that may be reflected back in the HTTP response. The device is also vulnerable to a stored cross-site scripting vulnerability that may allow session hijacking, disclosure of sensitive data, cross-site request forgery (CSRF) attacks, and remote code execution.

CVSS 3.1 · 5.4 Medium EPSS 1.7% KEV · Not listed
Vendors
Ge
Products
CVE-2019-18255

HMI/SCADA iFIX (Versions 6.1 and prior) allows a local authenticated user to modify system-wide iFIX configurations through section objects. This may allow privilege escalation.

CVSS 3.1 · 5.5 Medium EPSS < 1% KEV · Not listed
Vendors
Ge
Products
CVE-2019-18243

HMI/SCADA iFIX (Versions 6.1 and prior) allows a local authenticated user to modify system-wide iFIX configurations through the registry. This may allow privilege escalation.

CVSS 3.1 · 5.5 Medium EPSS < 1% KEV · Not listed
Vendors
Ge
Products
CVE-2019-13559

GE Mark VIe Controller is shipped with pre-configured hard-coded credentials that may allow root-user access to the controller. A limited application of the affected product may ship without setup and configuration instructions immediately available to the end user. The bulk of controllers go into applications requiring the GE commissioning engineer to change default configurations during the installation process. GE recommends that users reset controller passwords during installation in the operating environment.

CVSS 3.1 · 7.8 High EPSS < 1% KEV · Not listed
Vendors
Ge
CVE-2019-13554

GE Mark VIe Controller has an unsecured Telnet protocol that may allow a user to create an authenticated session using generic default credentials. GE recommends that users disable the Telnet service.

CVSS 3.1 · 8.8 High EPSS < 1% KEV · Not listed
Vendors
Ge
CVE-2019-10966

In GE Aestiva and Aespire versions 7100 and 7900, a vulnerability exists where serial devices are connected via an added unsecured terminal server to a TCP/IP network configuration, which could allow an attacker to remotely modify device configuration and silence alarms.

CVSS 3.1 · 5.3 Medium EPSS 1.3% KEV · Not listed
Vendors
Ge
CVE-2018-8867

In GE PACSystems RX3i CPE305/310 version 9.20 and prior, RX3i CPE330 version 9.21 and prior, RX3i CPE 400 version 9.30 and prior, PACSystems RSTi-EP CPE 100 all versions, and PACSystems CPU320/CRU320 RXi all versions, the device does not properly validate input, which could allow a remote attacker to send specially crafted packets causing the device to become unavailable.

CVSS 3.0 · 7.5 High EPSS 3.5% KEV · Not listed
Vendors
Ge
CVE-2018-5475

A Stack-based Buffer Overflow issue was discovered in GE D60 Line Distance Relay devices running firmware Version 7.11 and prior. Multiple stack-based buffer overflow vulnerabilities have been identified, which may allow remote code execution.

CVSS 3.1 · 9.8 Critical EPSS 3.8% KEV · Not listed
Vendors
Ge
CVE-2018-5473

An Improper Restriction of Operations within the Bounds of a Memory Buffer issue was discovered in GE D60 Line Distance Relay devices running firmware Version 7.11 and prior. The SSH functions of the device are vulnerable to buffer overflow conditions that may allow a remote attacker to execute arbitrary code on the device.

CVSS 3.1 · 9.8 Critical EPSS 5.9% KEV · Not listed
Vendors
Ge
CVE-2018-19003

GE Mark VIe, EX2100e, EX2100e_Reg, and LS2100e Versions 03.03.28C to 05.02.04C, EX2100e All versions prior to v04.09.00C, EX2100e_Reg All versions prior to v04.09.00C, and LS2100e All versions prior to v04.09.00C The affected versions of the application have a path traversal vulnerability that fails to restrict the ability of an attacker to gain access to restricted information.

CVSS 3.0 · 7.5 High EPSS 2.6% KEV · Not listed
Vendors
Ge
Products
CVE-2018-17925

Multiple instances of this vulnerability (Unsafe ActiveX Control Marked Safe For Scripting) have been identified in the third-party ActiveX object provided to GE iFIX versions 2.0 - 5.8 by Gigasoft. Only the independent use of the Gigasoft charting package outside the iFIX product may expose users to the reported vulnerability. The reported method shown to impact Internet Explorer is not exposed in the iFIX product, nor is the core functionality of the iFIX product known to be impacted.

CVSS 3.0 · 4.8 Medium EPSS < 1% KEV · Not listed
Vendors
Ge
Products
CVE-2018-15362

XXE in GE Proficy Cimplicity GDS versions 9.0 R2, 9.5, 10.0

CVSS 3.0 · 9.1 Critical EPSS 2.7% KEV · Not listed
Vendors
Ge
Products
CVE-2018-10615

Directory traversal may lead to files being exfiltrated or deleted on the GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior host platform.

CVSS 3.0 · 8.1 High EPSS 2.5% KEV · Not listed
Vendors
Ge
Products