CVE-2012-2598

Buffer overflow in the DiagAgent web server in Siemens WinCC 7.0 SP3 through Update 2 allows remote attackers to cause a denial of service (agent outage) via crafted input.

CVSS 2.0 · 4.3 Medium EPSS 1.8% KEV · Not listed
Vendors
Products
CVE-2012-2441

RuggedCom Rugged Operating System (ROS) before 3.3 has a factory account with a password derived from the MAC Address field in a banner, which makes it easier for remote attackers to obtain access by performing a calculation on this address value, and then establishing a (1) SSH or (2) HTTPS session, a different vulnerability than CVE-2012-1803.

CVSS 2.0 · 8.5 High EPSS 8.5% KEV · Not listed
Vendors
CVE-2014-1699

Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to cause a denial of service (monitoring-service outage) via malformed HTTP requests to port 4999.

CVSS 2.0 · 5.0 Medium EPSS 2.1% KEV · Not listed
Vendors
CVE-2014-1698

Directory traversal vulnerability in Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to read arbitrary files via crafted packets to TCP port 4999.

CVSS 2.0 · 5.0 Medium EPSS 3.5% KEV · Not listed
Vendors
CVE-2012-2597

Multiple directory traversal vulnerabilities in Siemens WinCC 7.0 SP3 before Update 2 allow remote authenticated users to read arbitrary files via a crafted parameter in a URL.

CVSS 2.0 · 4.0 Medium EPSS 2.3% KEV · Not listed
Vendors
Products
CVE-2014-1697

The integrated web server in Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to execute arbitrary code via crafted packets to TCP port 4999.

CVSS 2.0 · 7.5 High EPSS 5.3% KEV · Not listed
Vendors
CVE-2012-2596

The XPath functionality in unspecified web applications in Siemens WinCC 7.0 SP3 before Update 2 does not properly handle special characters in parameters, which allows remote authenticated users to read or modify settings via a crafted URL, related to an "XML injection" attack.

CVSS 2.0 · 5.5 Medium EPSS 1.5% KEV · Not listed
Vendors
Products
CVE-2014-1696

Siemens SIMATIC WinCC OA before 3.12 P002 January uses a weak hash algorithm for passwords, which makes it easier for remote attackers to obtain access via a brute-force attack.

CVSS 2.0 · 5.0 Medium EPSS 1.7% KEV · Not listed
Vendors
CVE-2013-6926

The integrated HTTPS server in Siemens RuggedCom ROS before 3.12.2 allows remote authenticated users to bypass intended restrictions on administrative actions by leveraging access to a (1) guest or (2) operator account.

CVSS 2.0 · 8.0 High EPSS 1.5% KEV · Not listed
Vendors
CVE-2013-6920

Siemens SINAMICS S/G controllers with firmware before 4.6.11 do not require authentication for FTP and TELNET sessions, which allows remote attackers to bypass intended access restrictions via TCP traffic to port (1) 21 or (2) 23.

CVSS 2.0 · 10.0 Critical EPSS 3.2% KEV · Not listed
Vendors
CVE-2012-2595

Multiple cross-site scripting (XSS) vulnerabilities in unspecified web applications in Siemens WinCC 7.0 SP3 before Update 2 allow remote attackers to inject arbitrary web script or HTML via vectors involving special characters in parameters.

CVSS 2.0 · 4.3 Medium EPSS 1.5% KEV · Not listed
Vendors
Products
CVE-2013-6840

Siemens COMOS before 9.2.0.8.1, 10.0 before 10.0.3.1.40, and 10.1 before 10.1.0.0.2 allows local users to gain database privileges via unspecified vectors.

CVSS 2.0 · 6.9 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2013-5944

The integrated web server on Siemens SCALANCE X-200 switches with firmware before 4.5.0 and X-200IRT switches with firmware before 5.1.0 does not properly enforce authentication requirements, which allows remote attackers to perform administrative actions via requests to the management interface.

CVSS 2.0 · 10.0 Critical EPSS 3.2% KEV · Not listed
Vendors
CVE-2012-1803

RuggedCom Rugged Operating System (ROS) 3.10.x and earlier has a factory account with a password derived from the MAC Address field in the banner, which makes it easier for remote attackers to obtain access by performing a calculation on this address value, and then establishing a (1) TELNET, (2) remote shell (aka rsh), or (3) serial-console session.

CVSS 2.0 · 8.5 High EPSS 48.9% KEV · Not listed
Vendors
CVE-2013-5709

The authentication implementation in the web server on Siemens SCALANCE X-200 switches with firmware before 5.0.0 does not use a sufficient source of entropy for generating values of random numbers, which makes it easier for remote attackers to hijack sessions by predicting a value.

CVSS 2.0 · 8.3 High EPSS 3.0% KEV · Not listed
Vendors
CVE-2012-1802

Buffer overflow in the embedded web server on the Siemens Scalance X Industrial Ethernet switch X414-3E before 3.7.1, X308-2M before 3.7.2, X-300EEC before 3.7.2, XR-300 before 3.7.2, and X-300 before 3.7.2 allows remote attackers to cause a denial of service (device reboot) or possibly execute arbitrary code via a malformed URL.

CVSS 2.0 · 7.8 High EPSS 6.1% KEV · Not listed
Vendors
CVE-2013-4943

The client application in Siemens COMOS before 9.1 Update 458, 9.2 before 9.2.0.6.37, and 10.0 before 10.0.3.0.19 allows local users to gain privileges and bypass intended database-operation restrictions by leveraging COMOS project access.

CVSS 2.0 · 7.2 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2013-4912

Open redirect vulnerability in Siemens WinCC (TIA Portal) 11 and 12 before 12 SP1 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks by leveraging improper configuration of SIMATIC HMI panels by the WinCC product.

CVSS 2.0 · 5.8 Medium EPSS 2.1% KEV · Not listed
Vendors