Search vulnerabilities

Results 122

Export CSV
CVE-2021-43552

Philips Patient Information Center iX (PIC iX) and Efficia CM Series Use of Hard-coded Cryptographic Key

The use of a hard-coded cryptographic key significantly increases the possibility encrypted data may be recovered from the Patient Information Center iX (PIC iX) Versions B.02, C.02, and C.03.

CVSS 3.1 · 6.1 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2021-43550

Philips Patient Information Center iX (PIC iX) and Efficia CM Series Use of a Broken or Risky Cryptographic Algorithm

The use of a broken or risky cryptographic algorithm is an unnecessary risk that may result in the exposure of sensitive information, which affects the communications between Patient Information Center iX (PIC iX) Versions C.02 and C.03 and Efficia CM Series Revisions A.01 to C.0x and 4.0.

CVSS 3.1 · 5.9 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2021-43548

Philips Patient Information Center iX (PIC iX) and Efficia CM Series Improper Input Validation

Patient Information Center iX (PIC iX) Versions C.02 and C.03 receives input or data, but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.

CVSS 3.1 · 6.5 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2021-39376

Philips Healthcare Tasy Electronic Medical Record (EMR) 3.06 allows SQL injection via the CorCad_F2/executaConsultaEspecifico IE_CORPO_ASSIST or CD_USUARIO_CONVENIO parameter.

CVSS 3.1 · 8.8 High EPSS 1.2% KEV · Not listed
Vendors
CVE-2021-33017

Philips IntelliBridge EC 40 and EC 80 Hub Authentication Bypass Using an Alternate Path or Channel

The standard access path of the IntelliBridge EC 40 and 60 Hub (C.00.04 and prior) requires authentication, but the product has an alternate path or channel that does not require authentication.

CVSS 3.1 · 8.1 High EPSS < 1% KEV · Not listed
Vendors
CVE-2021-32993

Philips IntelliBridge EC 40 and EC 80 Hub Use of Hard-coded Credentials

IntelliBridge EC 40 and 60 Hub (C.00.04 and prior) contains hard-coded credentials, such as a password or a cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data.

CVSS 3.1 · 8.1 High EPSS < 1% KEV · Not listed
Vendors
CVE-2020-7360

Philips SmartControl DLL Hijacking

An Uncontrolled Search Path Element (CWE-427) vulnerability in SmartControl version 4.3.15 and versions released before April 15, 2020 may allow an authenticated user to escalate privileges by placing a specially crafted DLL file in the search path. This issue was fixed in version 1.0.7, which was released after April 15, 2020. (Note, the version numbering system changed significantly between version 4.3.15 and version 1.0.7.)

CVSS 3.1 · 7.4 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2020-6007

Philips Hue Bridge model 2.X prior to and including version 1935144020 contains a Heap-based Buffer Overflow when handling a long ZCL string during the commissioning phase, resulting in a remote code execution.

CVSS 3.1 · 7.9 High EPSS 2.1% KEV · Not listed
Vendors
CVE-2020-16212

Philips Patient Monitoring Devices Exposure of Resource to Wrong Sphere

In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource. The application on the surveillance station operates in kiosk mode, which is vulnerable to local breakouts that could allow an attacker with physical access to escape the restricted environment with limited privileges.

CVSS 3.1 · 6.8 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2019-6562

In Philips Tasy EMR, Tasy EMR Versions 3.02.1744 and prior, the software incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users.

CVSS 3.1 · 5.4 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2019-18980

On Signify Philips Taolight Smart Wi-Fi Wiz Connected LED Bulb 9290022656 devices, an unprotected API lets remote users control the bulb's operation. Anyone can turn the bulb on or off, or change its color or brightness remotely. There is no authentication or encryption to use the control API. The only requirement is that the attacker have network access to the bulb.

CVE-2019-18263

An issue was found in Philips Veradius Unity, Pulsera, and Endura Dual WAN Router, Veradius Unity (718132) with wireless option (shipped between 2016-August 2018), Veradius Unity (718132) with ViewForum option (shipped between 2016-August 2018), Pulsera (718095) and Endura (718075) with wireless option (shipped between 26-June-2017 through 07-August 2018), Pulsera (718095) and Endura (718075) with ViewForum option (shipped between 26-June-2017 through 07-August 2018). The router software uses an encryption scheme that is not strong enough for the level of protection required.

CVSS 3.1 · 6.5 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2019-18241

In Philips IntelliBridge EC40 and EC80, IntelliBridge EC40 Hub all versions, and IntelliBridge EC80 Hub all versions, the SSH server running on the affected products is configured to allow weak ciphers. This could enable an unauthorized attacker with access to the network to capture and replay the session and gain unauthorized access to the EC40/80 hub.

CVSS 3.1 · 6.5 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2019-13557

In Tasy EMR, Tasy WebPortal Versions 3.02.1757 and prior, there is an information exposure vulnerability which may allow a remote attacker to access system and configuration information.

CVSS 3.1 · 5.3 Medium EPSS 1.2% KEV · Not listed
Vendors
CVE-2019-13546

In IntelliSpace Perinatal, Versions K and prior, a vulnerability within the IntelliSpace Perinatal application environment could enable an unauthorized attacker with physical access to a locked application screen, or an authorized remote desktop session host application user to break-out from the containment of the application and access unauthorized resources from the Windows operating system as the limited-access Windows user. Due to potential Windows vulnerabilities, it may be possible for additional attack methods to be used to escalate privileges on the operating system.

CVSS 3.1 · 6.8 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2019-13534

Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part #: M8096-67501, WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C) and WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C). The product downloads source code or an executable from a remote location and executes the code without sufficiently verifying the origin and integrity of the code.

CVSS 3.1 · 7.2 High EPSS < 1% KEV · Not listed
Vendors
Products
865240 865241 865242 and 16 more
CVE-2019-13530

Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part #: M8096-67501, WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C) and WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C). An attacker can use these credentials to login via ftp and upload a malicious firmware.

CVSS 3.1 · 7.2 High EPSS 1.4% KEV · Not listed
Vendors
Products
865240 865241 865242 and 16 more