Export limit exceeded: 425825 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search vulnerabilities

Results 824

Export CSV
CVE-2020-7474

A CWE-427: Uncontrolled Search Path Element vulnerability exists in ProSoft Configurator (v1.002 and prior), for the PMEPXM0100 (H) module, which could cause the execution of untrusted code when using double click to open a project file which may trigger execution of a malicious DLL.

CVSS 3.1 · 7.8 High EPSS < 1% KEV · Not listed
CVE-2020-28219

A CWE-522: Insufficiently Protected Credentials vulnerability exists in EcoStruxure Geo SCADA Expert 2019 (Original release and Monthly Updates to September 2020, from 81.7268.1 to 81.7578.1) and EcoStruxure Geo SCADA Expert 2020 (Original release and Monthly Updates to September 2020, from 83.7551.1 to 83.7578.1), that could cause exposure of credentials to server-side users when web users are logged in to Virtual ViewX.

CVSS 3.1 · 7.8 High EPSS < 1% KEV · Not listed
CVE-2020-28218

A CWE-1021: Improper Restriction of Rendered UI Layers or Frames vulnerability exists in Easergy T300 (firmware 2.7 and older), that would allow an attacker to trick a user into initiating an unintended action.

CVSS 3.1 · 6.5 Medium EPSS 1.1% KEV · Not listed
CVE-2020-28215

A CWE-862: Missing Authorization vulnerability exists in Easergy T300 (firmware 2.7 and older), that could cause a wide range of problems, including information exposures, denial of service, and arbitrary code execution when access control checks are not applied consistently.

CVSS 3.1 · 9.8 Critical EPSS 2.3% KEV · Not listed
CVE-2020-28213

A CWE-494: Download of Code Without Integrity Check vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when sending specially crafted requests over Modbus.

CVSS 3.1 · 8.8 High EPSS 1.2% KEV · Not listed
CVE-2020-28212

A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when a brute force attack is done over Modbus.

CVSS 3.1 · 9.8 Critical EPSS 2.8% KEV · Not listed
CVE-2020-28211

A CWE-863: Incorrect Authorization vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause bypass of authentication when overwriting memory using a debugger.

CVSS 3.1 · 7.8 High EPSS < 1% KEV · Not listed
CVE-2019-6859

A CWE-798: Use of Hardcoded Credentials vulnerability exists in Modicon Controllers (All versions of the following CPUs and Communication Module product references listed in the Security Notifications), which could cause the disclosure of FTP hardcoded credentials when using the Web server of the controller on an unsecure network.

CVSS 3.1 · 7.5 High EPSS 1.2% KEV · Not listed
CVE-2019-6858

A CWE-427:Uncontrolled Search Path Element vulnerability exists in MSX Configurator (Software Version prior to V1.0.8.1), which could cause privilege escalation when injecting a malicious DLL.

CVSS 3.1 · 7.8 High EPSS < 1% KEV · Not listed
Products
CVE-2019-6855

Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10), which could cause a bypass of the authentication process between EcoStruxure Control Expert and the M340 and M580 controllers.

CVSS 3.1 · 7.3 High EPSS < 1% KEV · Not listed
CVE-2019-6854

A CWE-287: Improper Authentication vulnerability exists in a folder within EcoStruxure Geo SCADA Expert (ClearSCADA) -with initial releases before 1 January 2019- which could cause a low privilege user to delete or modify database, setting or certificate files. Those users must have access to the file system of that operating system to exploit this vulnerability. Affected versions in current support includes ClearSCADA 2017 R3, ClearSCADA 2017 R2, and ClearSCADA 2017.

CVSS 3.1 · 7.8 High EPSS < 1% KEV · Not listed
Products
CVE-2019-6851

A CWE-538: File and Directory Information Exposure vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information from the controller when using TFTP protocol.

CVSS 3.1 · 7.5 High EPSS 29.1% KEV · Not listed
CVE-2019-6848

A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info), which could cause a Denial of Service attack on the PLC when sending specific data on the REST API of the controller/communication module.

CVSS 3.1 · 8.6 High EPSS 32.1% KEV · Not listed