Search vulnerabilities

Results 437

Export CSV
CVE-2026-73171

Authenticated Remote File Overwrite via Crafted Backup in Advantech EKI-1242EIMS

Nozomi Networks Labs identified a CWE-73: External Control of File Name or Path vulnerability in the backup-restore workflow of Advantech EKI-1242EIMS in firmware version V1.06.01 that allows a remote authenticated attacker to overwrite arbitrary files on the device filesystem by uploading a crafted backup archive through the web management interface.

CVSS 4.0 · 8.6 High EPSS < 1% KEV · Not listed
Vendors
CVE-2026-73172

Remote OS Command Injection Allowing Root Execution on Advantech EKI-1242 Firmware

Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in the edgserver management service of Advantech EKI-1242EIMS in firmware version V1.06.01 that allows a remote unauthenticated attacker to execute arbitrary OS commands as root via crafted requests to TCP port 5058.

CVSS 4.0 · 9.3 Critical EPSS 2.2% KEV · Not listed
Vendors
CVE-2026-73175

OPC UA Gateway Denial of Service via Uncontrolled Resource Consumption

Nozomi Networks Labs identified a CWE-400: Uncontrolled Resource Consumption vulnerability in the OPC UA gateway component of Advantech EKI-1242EIMS in firmware version V1.06.01 that allows an adjacent unauthenticated attacker to exhaust the server session pool and cause a complete denial of service to all legitimate OPC UA clients by opening multiple anonymous sessions.

CVSS 4.0 · 7.1 High EPSS < 1% KEV · Not listed
Vendors
CVE-2026-73177

Insufficient Firmware Image Verification Enables Arbitrary Firmware Installation on Advantech EKI-1242EIMS

Nozomi Networks Labs identified a CWE-345: Insufficient Verification of Data Authenticity vulnerability in the firmware upgrade mechanism of the Advantech EKI-1242EIMS in firmware version V1.06.01. The device accepts firmware images through the authenticated web management interface without performing any cryptographic signature or certificate verification. An authenticated administrator-level attacker can install arbitrary modified firmware on the device, enabling full persistent compromise of the platform.

CVSS 4.0 · 8.6 High EPSS < 1% KEV · Not listed
Vendors
CVE-2026-73169

Nozomi Networks Labs identified a CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Modbus transaction management interface of Advantech EKI-1242EIMS in firmware version V1.06.01 that allows a remote authenticated attacker to store malicious script content that executes in the browser of any administrator who later opens an affected management page.

CVSS 4.0 · 6.3 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2026-73174

Nozomi Networks Labs identified a CWE-319: Cleartext Transmission of Sensitive Information vulnerability in the edgserver management protocol of Advantech EKI-1242EIMS in firmware version V1.06.01 that allows a network-adjacent passive observer to intercept management traffic and recover sensitive device identity and network metadata in cleartext.

CVSS 4.0 · 8.7 High EPSS < 1% KEV · Not listed
Vendors
CVE-2026-79698

Advantech WISE-6610-NB Node-RED nodered_lib_apply command injection

A vulnerability was identified in Advantech WISE-6610-NB, WISE-6610-EB, WISE-6610-TB, WISE-6610-JB, WISE-6610-CB, WISE-6610-EL-NB, WISE-6610-EL-EB, WISE-6610-EL-TB, WISE-6610-EL-JB, WISE-6610-EL-CB, WISE-6610P-DEA, WISE-6610P-DNA and WISE-6610P-DTA 1.2.1_20251110. This vulnerability affects the function nodered_lib_apply of the component Node-RED Library. Such manipulation of the argument act leads to command injection. The attack can be launched remotely. The exploit is publicly available and might be used. Upgrading to version 1.2.4_20260821 is able to resolve this issue. It is advisable to upgrade the affected component. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product.

CVSS 4.0 · 9.4 Critical EPSS 3.2% KEV · Not listed
Vendors
Products
CVE-2026-79697

Advantech WISE-6610-NB Basic Station Certificate-Deletion basicstation_apply command injection

A vulnerability was determined in Advantech WISE-6610-NB, WISE-6610-EB, WISE-6610-TB, WISE-6610-JB, WISE-6610-CB, WISE-6610-EL-NB, WISE-6610-EL-EB, WISE-6610-EL-TB, WISE-6610-EL-JB, WISE-6610-EL-CB, WISE-6610P-DEA, WISE-6610P-DNA and WISE-6610P-DTA 1.2.1_20251110. This affects the function basicstation_apply of the component Basic Station Certificate-Deletion Handler. This manipulation of the argument act causes command injection. The attack can be initiated remotely. The exploit has been publicly disclosed and may be utilized. Upgrading to version 1.2.4_20260821 is able to mitigate this issue. Upgrading the affected component is advised. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product.

CVSS 4.0 · 9.4 Critical EPSS 4.9% KEV · Not listed
Vendors
Products
CVE-2026-2670

Advantech WISE-6610-NB Background Management openvpn_apply os command injection

A vulnerability was identified in Advantech WISE-6610-NB, WISE-6610-EB, WISE-6610-TB, WISE-6610-JB, WISE-6610-CB, WISE-6610-EL-NB, WISE-6610-EL-EB, WISE-6610-EL-TB, WISE-6610-EL-JB, WISE-6610-EL-CB, WISE-6610P-DEA, WISE-6610P-DNA and WISE-6610P-DTA 1.2.1_20251110. Affected is an unknown function of the file /cgi-bin/luci/admin/openvpn_apply of the component Background Management. Such manipulation of the argument delete_file leads to os command injection. The attack can be executed remotely. The exploit is publicly available and might be used. Upgrading to version 1.2.4_20260821 is able to address this issue. It is advisable to upgrade the affected component. The vendor explains: "The delete operation has been redesigned to map the requested file type to a fixed allowlisted path, require a numeric tunnel ID, reject invalid requests, and use the native filesystem API (fs.unlink) instead of constructing a shell command from request data."

CVSS 4.0 · 8.6 High EPSS 13.9% KEV · Not listed
Vendors
Products
CVE-2026-14162

Advantech|Hospital Quering Management - Missing Authentication

Hospital Queuing Management developed by Advantech has a Sensitive Data Exposure vulnerability, allowing unauthenticated remote attackers to access a specific URL to obtain API documentation.

CVSS 4.0 · 9.3 Critical EPSS < 1% KEV · Not listed
Vendors
CVE-2024-50370

A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "cfg_cmd_set_eth_conf" operation.

CVSS 3.1 · 9.8 Critical EPSS 1.5% KEV · Not listed
Vendors
CVE-2024-50369

A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "multiple_ssid_htm" API which are not properly sanitized before being concatenated to OS level commands.

CVSS 3.1 · 7.2 High EPSS 1.1% KEV · Not listed
Vendors
CVE-2024-50368

A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "basic_htm" API which are not properly sanitized before being concatenated to OS level commands.

CVSS 3.1 · 7.2 High EPSS 1.1% KEV · Not listed
Vendors
CVE-2024-50358

A CWE-15 "External Control of System or Configuration Setting" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by authenticated users by restoring a tampered configuration backup.

CVSS 3.1 · 7.2 High EPSS < 1% KEV · Not listed
Vendors
CVE-2022-3386

Advantech R-SeeNet Versions 2.4.17 and prior are vulnerable to a stack-based buffer overflow. An unauthorized attacker can use an outsized filename to overflow the stack buffer and enable remote code execution.

CVSS 3.1 · 9.8 Critical EPSS 1.6% KEV · Not listed
Vendors
Products
CVE-2022-3385

Advantech R-SeeNet Versions 2.4.17 and prior are vulnerable to a stack-based buffer overflow. An unauthorized attacker can remotely overflow the stack buffer and enable remote code execution.

CVSS 3.1 · 9.8 Critical EPSS 1.6% KEV · Not listed
Vendors
Products
CVE-2026-36226

Cross‑Site Scripting in Advantech WebAccess/SCADA Decryption Field Enables Sensitive Data Disclosure

Cross Site Scripting vulnerability in Advantech WebAccess/SCADA 8.0-2015.08.16 allows a remote attacker to obtain sensitive information via the decryption field in the Create New Project User component

CVSS 3.1 · 6.1 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2026-6888

SQL Injection Vulnerability

Successful exploitation of the SQL injection vulnerability could allow a remote authenticated attacker to execute arbitrary commands via a specific interface, potentially enabling the attacker to access, modify, or delete sensitive information within the database.

CVSS 3.1 · 7.2 High EPSS < 1% KEV · Not listed
Vendors